SLCT* and SLCT*/35 safety light curtains
Troubleshooting
2
7
1
6
9
5
2
0
1
7
-1
2
33
7
Troubleshooting
7.1
Troubleshooting
If a fault occurs, press the test contact (Reset). The receiver clears the fault state
by performing a system reset.
If this process does not correct the fault, attempt to return to normal mode by
switching off the power supply for at least 1 second, then switching it back on
again.
Warning!
Danger to life due to an absence of safety functions in the event of dangerous
failure
If a device has failed so dangerously that one or more safety functions can no
longer be guaranteed, the operational safety of the affected machine or plant is
impaired as a consequence.
■
Decommission the affected machine or plant and the sensor system and
secure them to prevent recommissioning.
■
Replace the defective device with an original device from Fuchs.
■
Send the defective device to Fuchs with a description of the fault.
Warning!
Danger to life as the result of an absence of functional inspections
If you resolve a fault and do not subsequently check whether the device and the
protective function it enables are functioning correctly, this can prevent the
protective equipment from working.
■
After resolving the error, carry out a functional inspection to ensure that the
protective equipment is functioning again correctly.
■
Repeat the test steps described for commissioning. See chapter 5.
SLCT* and SLCT*/35 safety light curtains