SLCT* and SLCT*/35 safety light curtains
Appendix
2
7
1
6
9
5
2
0
1
7
-1
2
37
Outputs on the receiver unit
Ambient conditions
Switching voltage
24 VDC (acting on the
contact)
24 VDC (acting on the
contact)
Input current
5 mA
5 mA
Actuation tim e
0.2 ... 1.2 s
0.2 ... 1.2 s
A/B mode receiver unit (see A/B mode transmitter unit)
Function
Mode B: 24 VDC, 5 mA
Mode B: 24 VDC, 5 mA
SLCT*
Standard detection range
SLCT*/35
Increased detection
range
OSSD output
Output format
PNP semiconductor,
monitored for short circuit
and crossed circuit
PNP semiconductor,
monitored for short circuit
and crossed circuit
Switching voltage
ON: U
B
- 2 V
OFF: < 1 V
ON: U
B
- 2 V
OFF: < 1 V
Switching current (m ax.)
ON: max. 0.1 A
OFF: < 5
µ
A
ON: max. 0.1 A
OFF: < 5
µ
A
Load inductance (max.)
1.0 H
1.0 H
Load capacitance (max.)
220 nF
220 nF
Note
The outputs are
permanently monitored
by short (max. 120
µ
s)
sampling pulses. You
must ensure that this has
no effect on the
downstream circuit.
The outputs are
permanently monitored
by short (max. 120
µ
s)
sampling pulses. You
must ensure that this has
no effect on the
downstream circuit.
Signal output
Output format
PNP, short-circuit proof
PNP, short-circuit proof
Switching current
0.1 A
0.1 A
SLCT*
Standard detection range
SLCT*/35
Increased detection
range
Ambient temperature
-35 ... 60
°
C (-31 ...
140
°
F)
-35 ... 60
°
C (-31 ...
140
°
F)
Storage temperature
-35 ... 70
°
C (-31 ... 158
°
F)
-35 ... 70
°
C (-31 ... 158
°
F)
Relative hum idity
Max. 95 %, not
condensing
Max. 95 %, not
condensing
SLCT*
Standard detection range
SLCT*/35
Increased detection