B) Total connection (in parallel)
(see fig. Below):
1x Main cable between Cerberus and amp,
made with 2-pole cable. Terminals made with
male NL4 connectors (+ 1 / -1 con 2 /
-2 empty), terminal towards the amplifier made
with male NL4 connector (+ 1 / -1 connected to
+1 red and -1 black on the amplifier and + 2 / -2
empty). Sections of poles: 2.5 sq mm minimum
section per pole up to a cable length of 15 m, in
addition we recommend switching to 4 sq mm
per pole.
2x Secondary cables, 2 poles, which connect
the 3 sub Ovoids together. Terminals made with
male NL4 connectors (+ 1 / -1 con 2 / -2
empty). Sections of the poles: section 2.5 mmq
per pole and cable length of 1.5 m
Parallel Connection
2p
IN
IN
DSP general settings:
Band pass:
High-pass filter @25Hz, 24 dB/oct But.
Low pass filter @100-120Hz, 24 dB/oct LR.
Gain and Time Alignment : it depends on Satel-
lite utilized
USER GUIDE
NL4FC ( +1 -1 )
NL4FC ( +1 -1 )
Amplifier + DSP