3 Wiring and Settings
Ovoid 15 has an input made with a female NL4 connector. Through a dedicated cable and termi-
nated with 2 male NL4Fc connectors it is connected directly to the output of the power amplifier.
The connectors are standard NL4 (+ 1 / -1 con 2 / -2 empty) or water proof on request.
In case of custom realization by the installer of the connection cables, we recommend specifying
installation-grade Low Smoke Zero Halogen (LSZH) cables for permanent installations.
The cables should use Oxygen Free Copper (OFC) of grade C11000 or above.
For distances of over 15 meters between Ovoid15 and amplifiers we recommend increasing the
section of the cable poles to 4 sq mm, to avoid excessive emission level losses. For lengths of less
than 15 m, you can use 2-pole cables, each with a section of 2.5 sqmm.
Connection diagrams:
A) 1x Ovoid15 (see fig.below):
Cable between Ovoid15 and amp (not supplied): 2-pole cable (2.5
sq mm minimum section per pole up to 15 m cable length, in addition we recommend switching to
4 sq mm for pole), terminated with Nl4Fc male connector (+ 1 / -1 connected and corresponding to
+1 red and -1 black on the amplifier, + 2 / -2 empty) to connect to the Ovoid15 input, which has an
NL4fc female connector, standard or WP on request.
Ovoid
NL4FC
NL4FC
2p
Ampli + DSP
( +1 -1 on ampli exit )
USER GUIDE