iQntrol DOS-MODBUS
Original manual in German Version 1.0.2 2022.10.06
19/39
8.1.5
Alarm
An alarm occurs; this is signalled by the
symbol in the OUT list. The alarm
relay is activated.
A differentiation is made between alarms (software alarms, e.g., alarm high, alarm
low) and disruptions (switch inputs).
In the event of alarms, the respective measuring value is illustrated in red.
In the event of disruptions, the corresponding symbol appears in the IN list.
Alarms or disruptions must be pending for approx. 5 seconds before an alarm is
triggered.
Tip
An alarm will be automatically deleted when its cause has been remedied. This is the case, e.g., if the empty chemical
container was replaced or if measuring water resumes its flow through the measuring cell.
However, the alarm Switch-off time monitoring must be acknowledged manually!
8.2
Main menu
Automatic
Returns to the automatic operation
Settings
For adjusting the control parameters and system settings
Service
Input and output test, system information
Login
Password entry for authorisation
The password level is displayed in the status line to the left of the date
Log
Event and calibration log, logging of measuring values, data export
Calibration
For calibration of the pH and redox electrode
8.2.1
Main menu
Settings
The picture below shows the time control variant
pH
Set pH regulation control parameter
Disinfection
Set disinfection control parameter
Dosing performance
Adjust the dosing performance to the basin size
Temperature
Set basin temperature control parameters
Dosing delay
Set the dosing delay
System
Date/ time, password, display, network, language, device ID
Flocculation
Activate the release for flocculation dosing