IC-02.1 card capture reader
5.4 Control
RS-485
interface lines have leads with contacts
1
(A RS-485)
and
2
(B RS-485) of
XT5
connector block of the card capture reader control board (see Figure 4).
An ACS controller controls the card capture reader by sending a signal to the
“Capture
card”
input of the card capture reader control board (contact
1
of the connector block
XT1
).
Card capture reader generates a
“Card captured”
signal (contact
1
of the connector block
XT2
) and in certain cases – signal
“Fault”
(contact
2
of the connector block
XT2
).
The
“Capture card”
input is controlled by output of “dry contact” type or “open collector” of
the ACS controller. The input is “normal open”, i.e. when a control signal is given the ACS
controller closes it to the “
GND
” contact (contact 2 of the connector block
XT1
).
Input parameters:
voltage at the open contact relative to “GND” ............................................. 5±0.5 V
voltage at the closed contact relative to “GND” .......................................max. 0.8 V
current via closed contact .....................................................................max. 1.5 mA
The “
Card captured”
and
“Fault”
outputs
–
of “dry contact” type. Each of these outputs is
one of two relay contacts. Other relay contacts are banded and connected to the
“COM”
output (contact
3
of the connector block
XT2
). The outputs are “normal open”, i.e. while
producing a signal the corresponding output is connected to
“COM”
contact
.
Output parameters:
max. voltage between the corresponding output and “
COM
” contact ......... 42 V
max. switched current ............................................................................. 200 mA
If an access card inserted into the (6) slot requires to be captured the ACS controller gives
a signal to the “
Capture card”
input
.
At this signal the electromagnet opens the shutter that
prevents an access into the card capture reader and the card falls into the card container
(9), i.e. the card capturing occurs. If the optic sensor sees that the card at the slot is
missing then the electromagnet will not actuate and the access into the card capture
reader will remain shut.
At the card falling into the card container the optic sensor registers the fact of card
capturing. Only in this case the card capture reader gives the
“Card captured”
signal to the
ACS controller. On receiving this signal the ACS controller deactivates the
“Capture card”
signal after which the card capture reader deactivates the
“Card captured”
signal
.
On cards capturing the container gets full. When it is full further cards capturing is blocked
till the captured cards are extracted from the container. In this case the card capture
reader generates the
“Fault”
signal for the ACS controller.
To resume capturing of guest cards it is necessary to extract the full container from the
card capture reader and empty the cards
If the container is free from cards but the card capture reader is still blocked a likely reason
for this could be failure of the card capture reader units. It is recommended to apply to the
PERCo Technical Support Department.
9