Sending control signal to the Stop input locks the rotor regardless of the signals at the Unlock
A (B) inputs.
Potential mode is recommended during operation from the ACS controller.
Regardless of the selected control mode, PASS A or PASS B signals are generated when
passing in one direction or the other. These signals can inform the ACS controller of the fact of
passage.
Emergency passage opening is performed by removing a low-level signal from the Fire
Alarm contact relative to the GND contact. Note:
When operating the speed gate from the ACS controller, it is recommended to connect the
RC-panel to the ACS controller.
The maximum allowed cable length of the RC-panel (ACS controller) is 40 meters.
The maximum allowed cable length of the power supply depends on its cross section and
must be:
•
for 1.5 mm² cable – 10 meters
•
for 2.5 mm² cable – 20 meters
Example of
connection to the
ACS
Example of one passage zone connection to the ACS controller
CT/L04.2
XT6
XT7
XT2
XT1
XT5
S1
XT4
OUT1
OUT2
IN
RC
RS-485
TCP
/ IP
+12V
NO1
С1
NС1
NO2
С2
NС2
IN1
GND
IN2
IN3
GND
IN4
FA
GND
DUA
DUSt
DUB
LdA
LdSt
LdB
Buzz
+12V
GND
B
A
GND
+12V
B
A
GND
+12V
LAN
TCP / IP
PS
GND
+12V
1
2
3
4
1 2 3 4
LEFT BUTTON
STOP BUTTON
RIGHT BUTTON
LEFT INDICATOR
STOP INDICATOR
RIGHT INDICATOR
BUZZER
1
2
3
4
Reader
#1
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
1
2
1
2
1
2
3
1
2
3
B
A
GND
+12V
Reader
#2
XP21
XP20
XP22
XP9
XP7
XP11
UNLOCK A
UNLOCK B
GND
PASS A
COMMON
PASS B
RTD-15,
RTD-16,
RTD-20
RC
WHITE
BLUE
GREEN
BROWN
YELLOW
ORANGE
RED
BLACK
COMMON
DIN-rail
RTD-20 Full height rotor turnstile