16
•
sliding panels automatically open during authorized passage and automatically close after
the passage;
•
when the power is turned off (power loss), the sliding panels remain in closed position and, if
necessary, can be manually moved apart (not locked).
2. Normally open mode (
XP2 (Mode1)
jumper is installed):
•
in the home position, speed gate sliding panels are in the open position, the passageway is
constantly opened;
•
the sliding panels automatically close and block the passageway in case of an unauthorized
passage attempts; they automatically reopen when the passageway is free;
•
when the power is turned off (power loss), the sliding panels remain in the open position and
do not interfere with the free passage through the speed gate.
The speed gate operation algorithm in the pulse control mode for a single pass in one
direction:
1. A command (a combination of control signals) is sent from the control device (RC-panel,
WRC-device, ACS-controller) to the inputs of the control board in order to perform a single
passage in one direction.
2. The microcontroller installed on the control board processes the received combination of
signals and generates a command to the speed gate actuating mechanism to authorize the
passage and activates passage granting indication.
3. Passage in the selected direction is authorized. The sliding panels are moved apart in the
normally closed operating mode. The
Holding time in the unlocked state
countdown starts
(8 seconds by default).
4. The passage is registered when the user enters the passageway. One of the
PASS A
or
PASS
B
relay outputs is activated for 250 ms according to the passage direction. User location in the
passageway is monitored by passage sensors.
Note:
In order to prevent contact with the sliding panels, the speed gate is equipped with the
danger zone detection. When the user is in this area, the opening or closing of the sliding
panels is blocked.
5. After the user walks through the opened sliding panels he/she gets into a safe zone; the
microcontroller of the control board sends a command to the speed gate actuating mechanism
to close the sliding panels and deactivates the passage granting indication. The sliding panels
are closed in normally closed operating mode.
6. The closing of the sliding panels does not occur if a new user has been authorized
in the
same passage
direction
while the first user is walking through the passageway, thus the new
user can immediately follow the first one.
Note:
To increase the passageway effectiveness, it is recommended to arrange separate
passage lanes for each direction. Passage directions for each passage lane can be
displayed on the front end indication blocks.
7. If the user does not enter the passageway during the
H
olding time in the unlocked state
,
the microcontroller on the control board sends a command to the speed gate actuating
mechanism to close the passageway. The sliding panels are closed in normally-closed
operating mode.
The speed gate operation algorithm in the pulse control mode in case of an unauthorized
passage in one direction:
1. When the user enters in the passageway zone, passage sensors register an unauthorized
passage.
2. The microcontroller that is installed on the control board processes the received combination
of signals and switches to the alarm mode. The audible alarm will be activated to prevent
unauthorized passage. In the normally open operating mode, the speed gate sliding panels will
move and lock the passage.