TTR-08A Electromechanical Tripod Turnstile
Note:
Pressing the button on the RC panel corresponds to the low-level signal supply to
the contacts (“
Unlock A
”, “
Unlock B
” and “
Stop
”) of the
XT1.L
connector block
relatively to the contact “
GND
”.
9.3 Operating modes of the turnstile at potential control mode
See Table 4 for the operating modes set from the RC panel. Setting the operating modes
for each direction is independent, i.e. setting the operating mode for one direction does not
change the operating mode set earlier for the opposite one.
If by the moment of passage through the turnstile the low level is present on the contact,
corresponding to the set passage direction, the turnstile remains open in the set direction.
For the ACS outputs note the following:
High level — contacts of the output relay are broken or the output transistor is
closed
Low level — contacts of the output relay are closed or the output transistor is
open.
Table 4. Potential control mode (the jumper is taken off from the J1 connector)
INDICATION
THE TURNSTILE
OPERATING
MODES
LEVELS ON THE
CONTACTS SHOULD
BE PROVIDED
ON THE RC
PANEL
ON THE LED
DISPLAY
TURNSTILE
STATUS
Both passage
directions are
locked (the
turnstile is locked
both for entry and
exit)
The high level —
on contacts
“Unlock A”
and
“Unlock B”
or low level —
on the contact
“Stop”
The red
indicator above
the
STOP
button is on
The “Red cross”
for each passage
direction and “Red
line” pictograms
are on
The turnstile is
locked
One of the
passage
directions is open
(the turnstile is
open for passage
in the set
direction)
The low level —
on the contact
corresponding
to the passage direction,
the high levels — on the
other contacts
The green
indicator above
the button of the
chosen passage
direction
«Left»
/
«Right»
is on
The “Green arrow”
in the chosen
passage direction
and “Green line”
pictograms are on
When the
passage
is completed,
the turnstile is
locked
Both passage
directions are
open (the turnstile
is open both for
entry and exit)
The low level —
on contacts
“Unlock A”
and
“Unlock B”.
The high level —
on the contact
“Stop”
The two green
indicators
(“Left” and
“Right”) are on
The “Green arrow”
for each passage
direction and
“Green line”
pictograms are on.
The turnstile
remains open
9.4 Actions in emergency
For urgent evacuation of people from business facilities in case of fire, natural calamities
and other emergencies, the additional emergency exit should be provided. Such
emergency exit can be the automatic anti-panic rotary section
BH-02
.
The additional emergency exit can be provided by the turnstile passage area. Construction
of the turnstile enables immediate clear of passage way without use of any special keys or
tools. By putting the
Fire
Alarm
signal to turnstile logic board the barrier arm automatically
falls down allowing the free exit.
The arm also drops down automatically at a power supply loss.