Assembly & Operation Manual
9.5 Troubleshooting
Possible faults, which can be cleared by the users themselves, are listed in Table 5.
Table 5. Possible faults and remedy
FAULT
POSSIBLE
CAUSE
REMEDY
At the power-up the turnstile
doesn’t work, and there is no
light indication on the turnstile
housing and the RC panel
No supply
voltage to the
CLB
Switch off the turnstile power supply from the
AC mains, open the turnstile housing cover.
Check the power cable serviceability and
reliability of its connection to the CLB
XT3
connector block
The turnstile is not controlled in
one of the directions, and there is
light indication on the turnstile
housing and on the RC panel
The CLB does not
receive a control
signal for this
direction
Switch off the turnstile power supply from the
AC mains, open the turnstile housing cover,
and remove the outer panel. Check the RC
panel / WRC kit / ACS controller cable
serviceability and reliability of its connection to
the CLB
XS1
connector block