Assembly & Operation Manual
X4-X6
(
ADD
) – connector blocks for connecting additional equipment (
X4
- for intrusion
detector connection,
X5
- Ready and Detect signal outputs;
X6
- the alarm relay output for low
voltage (low battery);
X7
(
CAN
) – socket for interface board and communication cable interconnection (9);
X8
(
INDICATION
) – indication cable connection socket (8);
XP1
– programming socket (not used during operation);
XP2
(
+12LED
) – the jumper of board outputs relay operation indication. If the jumper is fixed -
indication is
ON
, if removed – indication is
OFF
;
SA1
(
SETUP
) – a set of DIP switches:
1
– turnstile control mode selection:
ON
- pulse (set by default),
OFF
- potential,
2
– barrier arms turn force value selection:
ON
– hard (used when operating the turnstile in vehicles, in order to compensate for
possible barrier arms shaking and vibration when the vehicle is moving),
OFF
– soft (used when operating the turnstile on fixed surfaces, in rooms, offices, etc.),
set by default.
3
,
4
–
not used during operation, must be in the
OFF
position.
PWR
– green LED indicator for interface board power supply.
Table 1. Pin assignment of connector blocks
№
Legend
Assignment
Control board connector blocks
X1 (POWER)
1
+24
2
GND
Turnstile power supply 24V DC, 9A
Interface board connector blocks
X1(ACS)
1
+12OUT
2
GND
+12V power supply for additional equipment (siren)
3
A1
4
A2
«Alarm» relay output (siren connection)
5
C
Common for PASS relay outputs
6
Pass A
PASS A relay output (passage in A direction)
7
Pass B
PASS B relay output (passage in B direction)
X2 (RC)
1
GND
General
2
L
Control input - passage A permission
3
ST
Control input - passage denial
4
R
Control input - passage B permission
5
Led A
Passage A permission indication output on the RC-panel
6
Led ST
Passage denial indication output on the RC-panel
7
Led B
Passage B permission indication output on the RC-panel
8
Sound
RC-panel sound signal output
9
FA
10
GND
Emergency passage unblocking control input
X3 (LIGHT)
1
NO1
Normally open contact of the external
Light A
output
2
C1
Common contact of the external
Light A
output
3
NC1
Normally closed contact of the external
Light A
output
10