Assembly & Operation Manual
Horn-type and socket wrenches: S17, S13;
Torque wrench (8 - 25Nm);
SW3 Allen key (imbus);
90º set square;
Level;
Measuring tape (2m);
Note:
Other tools that do not reduce the required quality of installation work are allowed.
8.3 Length of cables
Table 3. Cables, used at the installation
№
Equipment
Cable
length, m,
max
Cable type
Cross-
section,
mm
2
, min
Example
1 Power supply
15
Twin cable
2.5
AWG 15; HO5VV-F 2×2.5
2
-
Fire Alarm
- Optional equipment
30 Twin
cable
0.2
RAMCRO SS22AF-T 2×0.22
CQR-2
3 RC-panel
40
Eight core cable
0.2
CQR CABS8 8×0.22c
4 ACS controller
30
Six core cable
0.2
CQR CABS6 6×0.22c
5 Grounding
10
Single core cable
1.5
Copper wire 1.5 mm
2
8.4 Installation procedure
The turnstile connection layout is given in Fig. 17. The connector blocks location on the control (9)
and interface (10) boards is given in Fig. 6 and 7. The cables used during installation and their
maximum lengths are indicated in Sect.
8.3. The installation surface and passage area
recommendations are given in Sect. 8.1. Follow this sequence of actions, when installing the
turnstile:
1. Unpack the turnstile and check the completeness as per Sect. 4.
2. Install the turnstile power supply to its designated place in accordance with its operational
documentation.
3. Route all cables in the cable ducts to the turnstile.
4. Install the mounting bracket or mounting post.
Caution!
It is necessary to correctly determine the turnstile installation height, when marking the
mounting of the
MT10.1
or
MT10.2
mounting brackets. The recommended turnstile
installation height should be approximately 900-950 mm from the floor to the upper edge of
the barrier arm.
a. Installation procedure for the
MT10.1
mounting bracket (
TTR-10AT
modification) (Fig. 14):
On vertical racks (pipes, handrails), mark and cut holes for fastening bolts (eight Ø7
through holes perpendicular to the bracket plane) and for the cable entry (Ø20 in one or
both racks). Use the turnstile bracket to mark the holes for cable entry if necessary.
When marking and installing the bracket, check the horizontal position using the level.
Pull the cables through the rack and through the corresponding bracket hole, the cable
outlet from the hole must be at least 30 cm long.
Use four M4×6 conical type screws to fasten the bracket back panel to the base.
Use two pads and M6×40 cylinder type screws to fasten the bracket to the racks. Use the
supplied anaerobic adhesive sealant for threaded connections fixation.
20