Assembly & Operation Manual
Indication on
Operating
mode
Operating signal
RC-panel
Turnstile status
Post
“One of the
passage
directions is
open”
The low level on the
contact
corresponding to the
passage direction,
the high level on the
other contacts.
The green
indicator of the
chosen
direction
“Left”
(
“Right”)
is on.
Green arrow in the
chosen passage
direction and green
line pictograms are
on.
The turnstile is unlocked
in the set direction.
“Both
passage
directions
are open”
The low level on
contacts
L
and
R
,
high level on
“ST”
contact
.
Both green
indicators “Left”
and “Right” are
on.
Green arrows for both
passage directions
and green line
pictograms are on.
The turnstile is unlocked
in both directions.
Note:
For ACS outputs:
High level — contacts of the output relay are open or the output transistor is closed.
Low level — contacts of the output relay are closed or the output transistor is open.
9.4 Actions in emergency
In emergency situations (for example, in the event of power supply failure), the turnstile passage
area can be used as an additional emergency exit.
It is possible to turn the turnstile into
Fire Alarm
mode from the emergency unblocking device (fire
alarm device, emergency button, etc.). In this mode, the turnstile barrier arm falls down (takes a
vertical position) allowing the free passage in both directions, LED display shows the green (for
1.25 sec) and red (for 0.25 sec) indicators, control commands from other devices and software are
ignored (Sect. 5.3.2).
The barrier arm is set into vertical position at a power loss as well.
Caution!
For urgent evacuation of people from facilities in case of fire, natural calamities or other
emergencies, the additional emergency exit should be provided. Such emergency exit can
be arranged with
BH-02
automatic anti-panic rotary section.
9.5 Troubleshooting
Possible faults, which can be cleared by the users themselves, are listed in Table 7.
Table 7. Possible faults and solutions
Fault
Possible cause
Solutions
At the power-up the
turnstile doesn’t work, and
there is no indication on
the turnstile housing and
the RC-panel.
No supply voltage to control board.
Switch off the turnstile power
supply, detach the turnstile
housing with the display unit from
the turnstile base. Check the
power cable serviceability and
reliability of its connection to the
X1
connector block on the control
board.
The turnstile is not
controlled in one of the
directions. The turnstile
housing and RC-panel
indication is on.
The interface board does not
receive a control signal for this
direction.
Switch off the turnstile power
supply, detach the turnstile
housing with the display unit from
the turnstile base. Check the RC-
panel / WRC / ACS controller
cable serviceability and reliability
of its connection
X2
connector
block on the interface board.
28