9  OPERATION INSTRUCTIONS 

 

DON’TS: 

  DO NOT carry through the gate items exceeding the passageway dimensions; 
  DO NOT subject the gate to strong impact; 
  DO NOT clean the gate with substances that may cause damage or corrosion of 

its parts. 

The gate leaf can be unlocked by the key of the lock or by pressing the button on the lock 
or  remotely  by  the  control  signal  from  the  ACS.  Locking  of  the  gate  is  performed 
automatically when the leaf is returned to its home (closed) position.  

The gate lock can work in 2 modes: 

 

normal: 

outside  the  lock  is  opened  with  a  key  or  remotely,  from  the  inside  the 

lock is opened by pressing the button and remotely. 

 

with  the  blocked  exit  button: 

opening  from  the  outside,  as  in  the  normal  mode, 

and  from the  inside  the  lock  is  only  opened  by  the  remote  control  signal,  since 
the exit button is fixed with the key in the normal position. 

The choice of the lock operation mode is carried out by a key from the inside through 
the  cylinder  mechanism  controlling  the  exit  button.  If  you  turn  the  key  counter-
clockwise 

until  it  stops

  and  then  remove  it  from  the  lock,  the  lock  will  go  into 

normal

 

mode,  if  you  turn  it  clockwise  to  the  stop  and  take  it  out,  then 

the  lock  will  go  into  the 

mode with the blocked exit button.

 

The absence of voltage does not affect the operation of the button or key. 

 
 

Summary of Contents for WHD-16

Page 1: ...INSTALLATION AND OPERATION MANUAL WHD 16 Full Height Security Gate...

Page 2: ...Full Height Security Gate WHD 16 Installation and Operation Manual...

Page 3: ...atures 8 5 2 Design and operation 8 6 MARKING AND PACKAGING 9 7 SAFETY REQUIREMENTS 9 7 1 Installation safety requirements 9 7 2 Operation safety requirements 9 8 INSTALLATION 10 8 1 General recommend...

Page 4: ...Abbreviations PS power supply ACS access control system 1 APLICATION The WHD 16 full height security gate is designed for management of pedestrian flows and access control at entrance points of facil...

Page 5: ...urrent 3 A Power consumption 36 W Throughput rate in the single passage mode 12 persons min Average daily throughput in the single passage mode 2 000 persons day Passageway dimensions H W 960 2000 mm...

Page 6: ...on request Power supply 1 MB 16 full height railing sections determined by the customer Fasteners 1 determined by the customer Anchor bolt SORMAT PFG IR 10 15 Finland 2 4 Note Technical characteristic...

Page 7: ...Installation and Operation Manual 6 Figure 1 General view of the WHD 16 gate 1 frame 2 leaf 3 electromechanical lock 4 door closer...

Page 8: ...WHD 16 Full Height Security Gate 7 Figure 2 Overall dimensions of the WHD 16 gate...

Page 9: ...through four mounting holes in the post flanges In the home position closed for entrance and exit the leaf provides complete closure of the passageway between the posts the lock is locked up After th...

Page 10: ...ed for installation Observe general electrical safety rules when laying out the cables Before the turnstile first power on make sure its installation and connection have been made accordingly Power su...

Page 11: ...00 mm for soft grounds using relevant mounting hardware for installation on different foundations making sure the mounting foundation is horizontal and flat the flatness deviation must not exceed 1 5...

Page 12: ...ble to the door sensor Fig 3 Figure 3 Mounting hole pattern 3 Insert sleeves for anchor bolts into the holes so that they do not stick out above the floor surface Attention Be extra cautious and caref...

Page 13: ...mended to install a door sensor reed switch The magnetic part of the sensor is installed in the leaf it is recommended the upper part of the leaf and the sensor itself is installed in the gate frame 8...

Page 14: ...opened with a key or remotely from the inside the lock is opened by pressing the button and remotely with the blocked exit button opening from the outside as in the normal mode and from the inside th...

Page 15: ...s high The gate should be stored indoors at ambient temperature from 40 C to 45 C and relative air humidity below 98 at 25 C The environment should be free of acid and alkali vapours or corroding gase...

Page 16: ......

Page 17: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Page 18: ...www perco com...

Reviews: