background image

Installation and Operation Manual 

5  DESIGN AND OPERATION 

5.1  Main features 

  possibility of remote gate unlocking;

 

  leaf reset by a hydraulic door closer after the passage; 

  wide  passageway  to  provide  controlled  passage  for  people  in  wheelchairs  (with  an 

attendant) and deliveries of large or bulky items; 

  Combined  coating  of  all  gate  elements  with  zinc  and  powder  paint  ensures  high 

corrosion resistance and long years of service in harsh environments; 

  durable polymeric powder coating protects the outside appearance; 

  unity  of  design  with 

RTD-16

  full  height  turnstiles  and 

MB-16

  railings  enables  various 

configurations of the entrance point to meet any required layout and dimensions; 

  together with 

RTD-16

 full height turnstiles, the gate can be used as an emergency exit. 

5.2  Design and operation 

The  gate  design  is  shown  in  Fig. 1.  Overall  dimensions  of  the  gate  are  given  in  Fig. 2. 
Unless  noted  otherwise,  the  position  numbers  in  the  Manual  agree  with  Fig. 1.  The  gate 
consists of: frame (1), leaf (2), electromechanical lock (3), door closer (4). 

The 

frame

 

(1) consisting of three joined vertical posts and 

the leaf

 

(2) are made of durable 

aluminium profile. The assembled gate is delivered with the 

rim

 

electric lock

 (3) mounted 

on the frame. During the installation, the hydraulic 

door closer 

(4) is mounted on the frame 

and  the  leaf.  The  gate  is  mounted  on  the  floor  with  anchor  bolts  driven  through  four 
mounting holes in the post flanges. 

In the home position

 

(closed for entrance and exit) 

– the leaf provides complete closure of 

the passageway between the posts, the lock is locked up. After the lock is unblocked, the 
gate can be opened outwards (the maximum opening angle of the leaf is 

120°). 

The  lock  is  unblocked 

mechanically

,  by  use  of  a  key  or  by  briefly  pressing  a  button 

located on the lock case (on the inside of the door) or 

remotely

 by emitting a control signal 

from an external device (ACS-controller) with a voltage of 12V and a duration 0.5 - 1 sec

.

 

The lock can be in the unblocked state indefinitely, while the leaf is open. 

The lock is blocked automatically when the leaf is returns to its home position

.

 

At the same 

time, the unblocking mechanism of the lock

 

is cocked for a next opening. 

To open the lock with a key from the inside

 

(the side of the door on which the lock case 

is  located),  it  is  necessary  to  turn  it  counterclockwise  until  it  stops  and  press  the  control 
button.  

If  you  then  remove  the  key  from  the  lock  cylinder  (in  this  leftmost  position),  subsequent 
unblocks can be made by pressing a button without using a key or remotely by applying a 
control voltage.  

If you turn the key in  the lock  clockwise  until it stops (in the rightmost  position) and then 
remove it, the operation of the control button is blocked and the lock can be opened again 
only with a key or remotely by applying a control voltage. 

To open the lock with a key from the outside of the gate

, turn the key clockwise until it 

stops - the lock is unlocked and the leaf can be opened.  

Summary of Contents for WHD-16

Page 1: ...INSTALLATION AND OPERATION MANUAL WHD 16 Full Height Security Gate...

Page 2: ...Full Height Security Gate WHD 16 Installation and Operation Manual...

Page 3: ...atures 8 5 2 Design and operation 8 6 MARKING AND PACKAGING 9 7 SAFETY REQUIREMENTS 9 7 1 Installation safety requirements 9 7 2 Operation safety requirements 9 8 INSTALLATION 10 8 1 General recommend...

Page 4: ...Abbreviations PS power supply ACS access control system 1 APLICATION The WHD 16 full height security gate is designed for management of pedestrian flows and access control at entrance points of facil...

Page 5: ...urrent 3 A Power consumption 36 W Throughput rate in the single passage mode 12 persons min Average daily throughput in the single passage mode 2 000 persons day Passageway dimensions H W 960 2000 mm...

Page 6: ...on request Power supply 1 MB 16 full height railing sections determined by the customer Fasteners 1 determined by the customer Anchor bolt SORMAT PFG IR 10 15 Finland 2 4 Note Technical characteristic...

Page 7: ...Installation and Operation Manual 6 Figure 1 General view of the WHD 16 gate 1 frame 2 leaf 3 electromechanical lock 4 door closer...

Page 8: ...WHD 16 Full Height Security Gate 7 Figure 2 Overall dimensions of the WHD 16 gate...

Page 9: ...through four mounting holes in the post flanges In the home position closed for entrance and exit the leaf provides complete closure of the passageway between the posts the lock is locked up After th...

Page 10: ...ed for installation Observe general electrical safety rules when laying out the cables Before the turnstile first power on make sure its installation and connection have been made accordingly Power su...

Page 11: ...00 mm for soft grounds using relevant mounting hardware for installation on different foundations making sure the mounting foundation is horizontal and flat the flatness deviation must not exceed 1 5...

Page 12: ...ble to the door sensor Fig 3 Figure 3 Mounting hole pattern 3 Insert sleeves for anchor bolts into the holes so that they do not stick out above the floor surface Attention Be extra cautious and caref...

Page 13: ...mended to install a door sensor reed switch The magnetic part of the sensor is installed in the leaf it is recommended the upper part of the leaf and the sensor itself is installed in the gate frame 8...

Page 14: ...opened with a key or remotely from the inside the lock is opened by pressing the button and remotely with the blocked exit button opening from the outside as in the normal mode and from the inside th...

Page 15: ...s high The gate should be stored indoors at ambient temperature from 40 C to 45 C and relative air humidity below 98 at 25 C The environment should be free of acid and alkali vapours or corroding gase...

Page 16: ......

Page 17: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Page 18: ...www perco com...

Reviews: