background image

Thank you for choosing the 

CYGNUS PRO

 Hybrid Fiber Optic tester as a part of 

your professional equipment for Broadcast installations. 

The

 CYGNUS PRO

 Hybrid Fiber Optic tester allows you to check the fiber optics 

and copper lines of an installation in a fast and easy way. Its operation is very 
simple.

To carry out the measuring you must connect the 

Cygnus Pro Main

 to the point 

you want to test and the 

Cygnus Pro Loop

 in the other end to close the circuit.

Elementos del Cygnus Pro

Thank you!

State 

indicators

Attenuation

Battery

Connector

Fiber optic and copper
lines information

Escape

Enter

Power up

Navigation

arrows

Connector

Aluminum body

Captive Screw

Cygnus Pro Main

Cygnus Pro Loop

2

13

Cygnus Pro Main Structures

Connector Pinout

Specifications

Specifications

Signal

Signal

Fiber

Fiber

Fiber
Fiber
Fiber

Fiber

Summary of Contents for CYGNUS PRO

Page 1: ...US PRO CYGNUS PRO Hybrid Fiber Optic Tester Permanyer Gri Connexions S L U Diputaci 203 bj 08011 Barcelona Spain Tel 34 93 451 78 30 Fax 34 93 323 75 88 mail central percon es http www percon es twitt...

Page 2: ...modo 1310nm Cygnus Pro Stratos HX1080 Neutrik OpticalCON Duo Monomodo 1310nm Neutrik OpticalCON Duo Monomodo 1550nm Neutrik OpticalCON Duo Multimodo 850nm Neutrik OpticalCON Duo Monomodo 1310nm SMPTE...

Page 3: ...out the measuring you must connect the Cygnus Pro Main to the point you want to test and the Cygnus Pro Loop in the other end to close the circuit Elementos del Cygnus Pro Thank you State indicators A...

Page 4: ...printed circuit that manages the operation of the tester Smaller size module that has one or several F O connections that link the optical ports of the connectors and one resistive shield between the...

Page 5: ...f there is a breakdown in the fiber line the device shows attenuation 18 flashing and increases the counter of fiber errors Shortcut in the copper lines If the device detects a shortcut in any of the...

Page 6: ...ST to CURRENT CURR If the tester does not detect any fault the counter is shown in green otherwise the number of errors will be shown in red The attenuation of the fiber is shown in green up to 5 99 d...

Page 7: ...suring configured in continuous mode CONT and history HIST It shows the cumulative errors in the copper lines the current status of the fiber and the number of fiber and copper errors detected until t...

Page 8: ...a correct SFP After the calibration the display shows the attenuation of the system once deducted the attenuation of the calibration 7 Cambio de Cabezal cambio conector The Cygnus Pro allows one main...