PTC0004
V. 01 – 01/04/2019
6
©Velleman nv
4.
Technical Specifications
power supply ........................................................................ 220-240 V~, 50/60 Hz
power consumption .................................................................................... 1200 W
dimensions ...................................................................................... 120 x 220 mm
weight ........................................................................................................ 1.3 kg
Information requirements for electric local space heaters
Model identifier(s):
Item
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage local
space heaters only (select one)
Nominal heat
output
P
nom
1,2
kW
manual heat charge control, with
integrated thermostat
no
Minimum heat
output
(indicative)
P
min
0,0
kW
manual heat charge control with room
and/or outdoor temperature feedback
no
Maximum
continuous heat
output
P
max,c
1,2
kW
electronic heat charge control with room
and/or outdoor temperature feedback
no
Auxiliary electricity consumption
fan-assisted heat output
no
At nominal heat
output
el
max
0,000
kW
Type of heat output/room temperature control
(select one)
At minimum heat
output
el
min
0,000
kW
single-stage heat output and no room
temperature control
no
In standby mode
el
SB
0,001
kW
two or more manual stages, no room
temperature control
no
with mechanic thermostat room
temperature control
no
with electronic room temperature control
yes
electronic room temperature control plus
day timer
no
electronic room temperature control plus
week timer
no
Other control options (multiple selections
possible)
room temperature control, with presence
detection
no
room temperature control, with open
window detection
no
with distance control option
no
with adaptive start control
no
with working time limitation
no
with black bulb sensor
no
Contact details
Velleman NV
Legen Heirweg, 33 9890 Gavere, Belgium