background image

3

CONTROL PADS ON THE DEHUMIDIFIER

NOTE: 

The control 

panel of the unit 

you purchased 

may be slightly 

different according 

to the models.

Bucket Full

Indicator Light

Auto Defrost ON 

Indicator Light

6                                                   

7

9

10

1

2

4

5

3

2

TIMER

8

On

Off

Defrost Full

CONT.

POWER

PUMP COMFORT FILTER

TURBO

ION

CONTROL PADS: 

When you push the button to change 

operation modes, the unit will make a single “beep” 

sound to indicate that it is changing modes.

  1. POWER 

 

Press to turn the dehumidifier on and off.

   2.  / : UP/DOWN PADS / HUMIDITY SET CONTROL PADS

 • 

The humidity level can be set within a range  

of 35%RH to 85%RH (Relative Humidity) in  

5% increments.

 • 

For drier air, press the   pad and set to a lower 

percent value (%).

 • 

For damper air, press the   pad and set a higher 

percent value (%).

 • 

The recommended standard setting is 45-50%. 

You must be on Normal mode to set the humidity

 • 

Cannot be used on COMFORT or CONT. mode.

  3. DISPLAY 

 

Shows the set % humidity level from 35% to 85% 

or auto on/off time (0-24) while setting, then  

shows the actual ( +/- 5% accuracy) room % 

humidity level in a range of 30%RH to 90%RH 

(Relative Humidity).

  4. TIMER 

 

Press to initiate the Auto on and Auto off 

feature, in conjunction with the   and   key pads. 

Timer range is 0.0 – 24 hrs. Timer does not cycle. 

Indicator(s) above the button ("On" and/or "Off") 

will illuminate when the operation is active.

 5. CONTINUOUS (CONT.) 

 

Press to activate the 

continuous dehumidifying operation. When 

operating in this mode the UP/DOWN  / pads 

will be deactivated and you will NOT be able to 

set a desired humidity. The unit will run non-stop 

unless using the bucket to collect water. At which 

point, the unit will shut off when the bucket is full. 

Indicator above the button will illuminate when the 

operation is active.

  6. PUMP 

 

Press to activate the pump operation. 

NOTE: Make sure the pump drain hose is installed 

into the unit and the continuous drain hose is 

removed from the unit before the pump operation 

is activated. When the bucket is full, the pump 

will initiate. Refer to the next pages for removing 

the collected water. Do not use this operation 

when the outdoor temperature is equal to or less 

than 32ºF (0ºC). Indicator above the button will 

illuminate when the operation is active.

 7. COMFORT 

 

Utilize this dehumidification feature to 

automatically keep humidity in the 45%–55% 

range based on room temperature. When 

operating in this mode the UP/DOWN  /  pads 

will be deactivated and you will NOT be able to set 

a desired humidity. Indicator above the button will 

illuminate when the operation is active.

  8. FILTER 

 

The check filter feature is a reminder to 

clean the Air Filter for more efficient operation. 

The “Filter” light (Clean Filter Indicator Light) will 

illuminate after 250 hours of operation. To reset 

after cleaning the filter, press and hold the Filter 

button and the light will go off, resetting the timer. 

Indicator above the button will illuminate when the 

operation is active.

  9. TURBO 

 

Press to select Turbo fan speed for 

maximum moisture removal. When the humidity 

has been reduced and quiet operation is preferred, 

set the fan control to Normal by pressing the 

TURBO pad to turn off Turbo fan/light. Indicator 

above the button will illuminate when the 

operation is active.

 10. ION 

 

Press to activate the ionizer. Negatively 

charged ions (anions) are automatically generated 

by ionization. These ions deactivate airborne 

chemical vapors and dust particles. Press the pad 

again to stop the function. Indicator above the 

button will illuminate when the operation is active.

 

 NOTE: 

When not in COMFORT or CONT. mode, the 

unit operates in NORMAL mode. Utilize this mode 

if you would like the unit to cycle on and off based 

on the relative humidity setting you have manually 

selected. (See numbers 2 and 3 above.) In 

NORMAL mode, both the “Comfort” and “Cont.” 

Indicator lights will not be illuminated.

FIG. 1

Summary of Contents for 4PADP95

Page 1: ...IER USER MANUAL Be sure to read the QUICK START TIPS on the next page FOR MODEL 4PADP95 Before using your dehumidifier please read this manual carefully and keep it for future reference along with you...

Page 2: ...g you to properly set up and begin to use your dehumidifier 1 The dehumidifier should be kept upright If for any reason it has not been stored upright while in your possession put the unit in an uprig...

Page 3: ...purchased may be slightly different NOTE The design and specifications of the dehumidifier are subject to change without prior notice for product improvement Contact Consumer Services at 844 472 2473...

Page 4: ...Failing to do so may cause fire and electric shock You should never try to take apart or repair the unit by yourself This may cause failure of machine or electric shock Before cleaning turn off the p...

Page 5: ...two weeks Operation without filters may cause failure If water enters the unit turn unit off disconnect power and contact a qualified service technician This may cause failure of dehumidifier and ther...

Page 6: ...lled into the unit and the continuous drain hose is removed from the unit before the pump operation is activated When the bucket is full the pump will initiate Refer to the next pages for removing the...

Page 7: ...light will be lit up only when the accumulated operation time achieves 250 hours or more The CLEAN FILTER Indicator light flashes once every second After cleaning the air filter press and hold the FI...

Page 8: ...E FLOAT DOES IT NEED THE FOAM PIECE INSIDE OF IT Inside the bucket on the left side is an arm mechanism that wobbles This piece is called the float DO NOT remove the foam piece that is found in the pl...

Page 9: ...USING THE UNIT A dehumidifier operating in one room will have little or no effect in drying an adjacent enclosed area such as a closet or other room unless there is adequate circulation of air in and...

Page 10: ...er can be automatically emptied into a floor drain by attaching a water hose garden hose or dehumidifier drain hose to the dehumidifier Garden hose must be 5 16 with a female threaded end with ID M 1...

Page 11: ...unit for pump draining to start NOTES The pump operation on light blinks at 1Hz when the pump is in operational failure Please turn off the unit and unplug the power cord Check the following items Cle...

Page 12: ...with clean water and add a small amount of mild detergent Swish it around in the bucket empty and rinse NOTE DO NOT use a dishwasher to clean the bucket After cleaning the bucket it must be securely i...

Page 13: ...WATER Be sure unit is not too large or too small for the area of the room When first installed run unit on Continuous Mode for 24 hours Allow enough time for unit to remove moisture Set humidity low e...

Page 14: ...is obstructing hose connection and there are no kinks or tears in any of the hosing Ensure unit is level and not tilted forward and that bucket is pushed in all the way Though the unit may appear lev...

Page 15: ...12...

Page 16: ...y Perfect Aire LLC 5401 Dansher Rd Countryside IL 60525 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_4PA...

Reviews: