 ERROR AND PROTECTION CODES

 AS –  HUMIDITY SENSOR ERROR

  

Unplug the unit for at least 5 minutes and plug 

it back in. Make sure the filter is clean. If error 

repeats, call Perfect Aire Consumer Services at 

844.472.2473.

 ES –  TEMPERATURE SENSOR ERROR

  

Unplug the unit for at least 5 minutes and plug 

it back in. Make sure the filter is clean. If error 

repeats, call Perfect Aire Consumer Services  

at 844.472.2473.

 

P2 –  BUCKET IS FULL OR NOT IN THE CORRECT POSITION

 

Empty the bucket and replace it in the proper 

position. Ensure float switch and foam are 

secured properly in bucket.

E3 –   UNIT MALFUNCTION

 

Unplug the unit for at least 5 minutes and plug 

it back in. If error repeats, call Perfect Aire 

Consumer Services at 844.472.2473.

 

EC –  BUCKET IS REMOVED OR NOT IN RIGHT POSITION

  

Replace bucket in the right position.

 OTHER FEATURES

BUCKET FULL INDICATOR LIGHT 

Illuminates when the bucket needs to be emptied, is 

removed, or is not placed in the proper position.

AUTO SHUT OFF 

The dehumidifier shuts off after 30 seconds when the 

bucket is full or when the bucket is removed or not 

replaced in the proper position. When the humidity 

setting is reached, the unit will cycle off automatically. 

(The compressor cycles off first. 3 minutes later, the fan 

will turn off as well.)

AUTO DEFROST 

When frost builds up on the evaporator coils, the 

compressor will cycle off and the fan will continue to 

run (on “Turbo”) until the frost disappears. The AUTO 

DEFROST Indicator light will illuminate. The unit will 

restart on its own once the auto defrost process  

has completed.

SAFETY FEATURE 

After the unit has stopped, it cannot resume operation 

within in the first 3 minutes. This is to protect the unit. 

Operation will restart automatically after 3 minutes.

CHECK FILTER FEATURE 

The system starts to log the time once the fan motor 

operates. The check filter light will be lit up only when 

the accumulated operation time achieves 250 hours or 

more. The CLEAN FILTER Indicator light flashes once 

every second. After cleaning the air filter, press and hold 

the FILTER button to reset the filter timer and turn off 

the CLEAN FILTER indicator light.

AUTO-RESTART 

If the unit breaks off unexpectedly due to a loss of 

power, it will automatically restart with the previous 

function setting when the power resumes.

SETTING THE TIMER

•  When the unit is on, press the TIMER button; the 

TIMER OFF indicator light illuminates, indicating that 

the Auto Stop program is initiated. Press it again and 

the TIMER ON indicator light illuminates indicating 

that the Auto Start program is initiated.

•  If you prefer, you can set the timer while the unit is 

powered off and follow the instructions above to set 

the unit to go on and then off.

•  Press or hold the UP or DOWN pad to change the 

Auto time by 0.5 hour increments, up to 10 hours, 

then at 1 hour increments up to 24 hours. The 

display on the control pad will count down the time 

remaining until start/stop.

•  The selected time will register for 5 seconds and the 

system will automatically revert back to displaying 

the previous humidity setting.

•  When the Auto start and Auto stop times are set 

within the same program sequence, TIMER ON and 

OFF indicator lights illuminate, identifying both ON 

and OFF times are now programmed. You can set the 

Timer for just ON or just OFF in which case the single 

corresponding ON or OFF light will be illuminated.

•  Turning the unit ON or OFF at any time or  

adjusting the timer setting to 0.0 will cancel the  

Auto Start/Stop.

•  When LED display window displays the code of P2, 

the Auto Start/Stop function will also be canceled. 

A NOTE ABOUT THE TIMER:  

When you set the timer, the unit will only go on once 

and off once. If you want the dehumidifier to cycle on 

and off repeatedly, you do not need to set the timer. 

Instead, set your desired humidity and the unit will cycle 

on and off based on the selected humidity setting.

Summary of Contents for 4PADP95

Page 1: ...IER USER MANUAL Be sure to read the QUICK START TIPS on the next page FOR MODEL 4PADP95 Before using your dehumidifier please read this manual carefully and keep it for future reference along with you...

Page 2: ...g you to properly set up and begin to use your dehumidifier 1 The dehumidifier should be kept upright If for any reason it has not been stored upright while in your possession put the unit in an uprig...

Page 3: ...purchased may be slightly different NOTE The design and specifications of the dehumidifier are subject to change without prior notice for product improvement Contact Consumer Services at 844 472 2473...

Page 4: ...Failing to do so may cause fire and electric shock You should never try to take apart or repair the unit by yourself This may cause failure of machine or electric shock Before cleaning turn off the p...

Page 5: ...two weeks Operation without filters may cause failure If water enters the unit turn unit off disconnect power and contact a qualified service technician This may cause failure of dehumidifier and ther...

Page 6: ...lled into the unit and the continuous drain hose is removed from the unit before the pump operation is activated When the bucket is full the pump will initiate Refer to the next pages for removing the...

Page 7: ...light will be lit up only when the accumulated operation time achieves 250 hours or more The CLEAN FILTER Indicator light flashes once every second After cleaning the air filter press and hold the FI...

Page 8: ...E FLOAT DOES IT NEED THE FOAM PIECE INSIDE OF IT Inside the bucket on the left side is an arm mechanism that wobbles This piece is called the float DO NOT remove the foam piece that is found in the pl...

Page 9: ...USING THE UNIT A dehumidifier operating in one room will have little or no effect in drying an adjacent enclosed area such as a closet or other room unless there is adequate circulation of air in and...

Page 10: ...er can be automatically emptied into a floor drain by attaching a water hose garden hose or dehumidifier drain hose to the dehumidifier Garden hose must be 5 16 with a female threaded end with ID M 1...

Page 11: ...unit for pump draining to start NOTES The pump operation on light blinks at 1Hz when the pump is in operational failure Please turn off the unit and unplug the power cord Check the following items Cle...

Page 12: ...with clean water and add a small amount of mild detergent Swish it around in the bucket empty and rinse NOTE DO NOT use a dishwasher to clean the bucket After cleaning the bucket it must be securely i...

Page 13: ...WATER Be sure unit is not too large or too small for the area of the room When first installed run unit on Continuous Mode for 24 hours Allow enough time for unit to remove moisture Set humidity low e...

Page 14: ...is obstructing hose connection and there are no kinks or tears in any of the hosing Ensure unit is level and not tilted forward and that bucket is pushed in all the way Though the unit may appear lev...

Page 15: ...12...

Page 16: ...y Perfect Aire LLC 5401 Dansher Rd Countryside IL 60525 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_4PA...

Reviews: