AIR CONDITIONER FEATURES

Thoroughly familiarize yourself with the control panel as shown below and all of its functions. Afterwards, follow the 

symbol for the functions you desire. This unit can be controlled by the unit control or the remote control.

NOTE: 

This manual does not include Remote Control Operations; See the Remote Control Instructions packed with the 

unit for details.

1. POWER button

Power switch ON/OFF.

2. MODE select button

Selects the appropriate operating mode. Each time you 

press the button, a mode is selected in a sequence 

that goes from AUTO, COOL, DRY, and FAN. The mode 

indicator light illuminates next to the different mode 

settings. NOTE: On DRY mode, you can adjust the 

humidity for models with humidity sensor only.

3. SLEEP (ECO)/FILTER button

Used to initiate the SLEEP/ECO operation.
NOTE: After 250 hours of operation, the filter indicator 

light illuminates. This feature is a reminder to clean the 

Air Filter for more efficient operation. Press this button 

for 3 seconds to cancel the reminder.

4. UP (+) and DOWN (—) buttons

Used to adjust (increase/decrease) temperature settings 

(1°F/1°C increments) in a range of 62°F (17°C) to 86°F 

(30°C) or to set the TIMER setting in a range of 0 – 24 

hours or the humidity settings in a range of 35% RH 

(Relative Humidity) to 85% RH in 5% increments (only 

for models with humidity sensor). 

NOTE: 

The control is capable of displaying the 

temperature in degrees Fahrenheit or degrees Celsius. 

To convert from one to the other, press and hold the Up 

and Down buttons at the same time for 3 seconds.

5. TIMER button

Used to initiate the AUTO ON start time and AUTO OFF 

stop time program, in conjunction with the (+) and (—) 

buttons. The timer ON/OFF indicator light illuminates 

next to the timer ON/OFF settings.

6. FAN button

Control the fan speed. Press to select one of three fan 

speeds: LOW, HI or AUTO. The fan speed indicator light 

illuminates under different fan settings except AUTO 

speed. When AUTO fan speed is selected all of the fan 

indicator lights go dark.
NOTE: Press this button for 3 seconds to initiate ION 

feature. The ion generator is energized and will help to 

remove pollen and impurities from the air, trapping  

them in the filter. Press it for 3 seconds again to stop 

the ION feature.

7. SWING button

Used to initiate the Auto Swing feature. When the 

operation is ON, press the SWING button to stop the 

louver at a desired angle.  

INDICATOR LIGHTS

Timer ON light

Degrees Celsius

Timer OFF light

Degrees Fahrenheit

Dry mode light

Humidity (on some  

models only)

Auto mode light

Low fan speed light

Fan mode light

High fan speed light

Cool mode light

Filter light

Follow Me light

Sleep mode light

FIG. 28

Summary of Contents for PORTQ12000

Page 1: ...PORTABLE AIR CONDITIONER FOR MODEL PORTQ12000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Page 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Page 3: ...listed in the accessories chart of this Instruction Manual ENERGY SAVING TIPS Use the unit in the recommended room size Locate the unit where furniture cannot obstruct the air flow Keep blinds curtai...

Page 4: ...replacement work should be performed by authorized personnel only Installation and repair work must be performed in accordance with the national wiring standards by authorized personnel only DO NOT op...

Page 5: ...be pulled into water or any other liquid If the unit does ever fall into water unplug it immediately DO NOT install the unit in a location that may be exposed to combustible gas or other flammable li...

Page 6: ...c Security Bracket and 2 Screws 1 set Drain Hose 1 pc Power Cord Buckle 1 pc ON OFF TEMP S HO R T C U T T IME R O N T IME R O F F MO DE FAN S L E E P S W ING L E D Remote Control and Batteries 1 set N...

Page 7: ...e following 1 Plug in the air conditioner 2 The power supply cord will have TWO buttons on the plug head Press the TEST button The RESET button will click as it pops out 3 Press the RESET button again...

Page 8: ...for you to improvise or modify some aspects of the installation procedures for certain types of windows Please refer to Fig 6 and Fig 7 for minimum and maximum window openings Window slider kit length...

Page 9: ...t of the exhaust hose 20 inch clearance in order to ensure the exhaust system works properly Fig 12 Once the Exhaust Hose assembly and Adjustable Window Slider are prepared choose from one of the foll...

Page 10: ...he glass and the window frame to prevent air and insects from getting into the room STEP 4 Fig 16 If desired install the security bracket with 2 screws as shown STEP 5 Fig 17 Insert the window slider...

Page 11: ...the glass and the window frame to prevent air and insects from getting into the room STEP 4 Fig 21 If desired install the security bracket with 2 screws as shown STEP 5 Fig 22 Insert the window slider...

Page 12: ...so there are no leaks Direct the hose toward a floor drain making sure that there are no kinks that will stop the water flow Place the end of the hose into a drain and make sure the end of the hose is...

Page 13: ...the hose directly over the drain area in your basement floor or over a shallow pan if no floor drain is available See Fig 23 24 Remove the plug from the bottom drain outlet the water in the bottom tra...

Page 14: ...y settings in a range of 35 RH Relative Humidity to 85 RH in 5 increments only for models with humidity sensor NOTE The control is capable of displaying the temperature in degrees Fahrenheit or degree...

Page 15: ...es until the FOLLOW ME button is pressed again If the unit does not receive the Follow Me signal during any 7 minute interval the unit will beep to indicate use of the Follow Me feature has ended The...

Page 16: ...uto timer settings ad the humidity settings for models with humidity sensor only when on DRY and FAN modes it shows the room temperature It also shows the following Error and Protection Codes ERROR AN...

Page 17: ...filter Refer to Care and Cleaning section To defrost set to FAN only mode Thermostat is set too cold for night time cooling To defrost the coil set to FAN only mode Then set temperature to a higher se...

Page 18: ......

Page 19: ......

Page 20: ...Perfect Aire LLC 5401 Dansher Rd Countryside IL 60525 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_PORTQ...

Reviews: