14
NOTE
A highly recommended troubleshoot for any issue in general consists of turning off unit and unplugging for 5
minutes. It is also recommended to try another wall outlet. For further assistance, contact Consumer Services
at 844-472-2473.
TROUBLESHOOTING
BEFORE CALLING FOR SERVICE, PLEASE REVIEW THE CHART BELOW
ISSUE
POSSIBLE CAUSES
AIR CONDITIONER NOT
COOLING ROOM, OR NOT BLOWING
COLD AIR
• Be sure unit is not too large or too small for the area of the room.
• Verify that all doors, windows, curtains and any other openings are closed.
Verify nothing is obstructing the front grille of unit, such as curtains, etc.
• Allow enough time for room to cool, especially if outside temp is very high.
• Check that the filter is not dirty and louvers are open all the way and blowing in the
desired direction.
• Check that unit is set to COOL mode and that temperature is down enough (but
not too low).
• If unit is near a heat source, such as a stove, etc., relocate unit.
• If air coming from unit is cool to the touch, then unit is working properly; please
double check the first three bullet points above.
• If using Follow Me remote feature, move remote away from unit.
• Unplug unit for at least 5 minutes. Follow Reset instructions on plug.
AIR CONDITIONER COOLING
BUT ROOM IS TOO WARM - ICE
FORMING ON COOLING COIL
BEHIND DECORATIVE FRONT
• Outdoor temperature is below 64ºF (18ºC). To defrost the coil, set to FAN
only mode.
• Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost,
set to FAN only mode.
• Thermostat is set too cold for night-time cooling. To defrost the coil, set to FAN
only mode. Then, set temperature to a higher setting.
AIR CONDITIONER CYCLING ON
AND OFF TOO FREQUENTLY OR
NOT ENOUGH
• Be sure unit is not too large or too small for the area of the room.
• Make sure nothing is blocking the louvers.
• Make sure there is no dirt or debris inside the unit or on the filter.
UNIT WILL NOT TURN ON
• If P1 Error code appears, drain water from bottom tray
• Reset circuit breaker. Make sure there are not too many items (i.e. lamps, TV’s,
etc.) working off the same breaker.
• Check plug connection.
• If plug is operating on an on/off switch, be sure that the switch is ‘on’.
• Try plugging unit into another outlet.
• Check the temperature setting.
• Unplug unit for at least 5 minutes. Follow Reset instructions on plug.
UNIT BLOWS FUSES OR POPS
CIRCUIT BREAKER
• Make sure there are enough available amps on the circuit for the air conditioner.
• Large units which run on a 230v will require a dedicated 20 or 30 amp circuit.
AIR CONDITIONER IS
MAKING NOISES
• Check to be sure the unit is free from debris. Verify nothing is obstructing the unit.
• Check the fan blade for cracks or chips.
• Make sure the window slider kit is properly and securely mounted inside
the window.
• Clean the air filter.
REMOTE SENSING / FOLLOW ME
DEACTIVATING PREMATURELY
• Remote control not located within range. Place remote control within 20 ft and
180º radius of the front of the unit.
• Remote control signal obstructed. Remove obstruction.
• Replace batteries in remote control with a fresh set of batteries.