background image

Index

A

Analytes 

11

Assays 

11

B

Barcodes

plate 

10

sample 

10

C

Camera 

6

Capacity 

10

Connectors 

12

D

DBS 

1

Decommissioning 

14

Decontamination 

8

Disk detector 

7

Dried blood disk 

1

E

EMC 

11

Environmental conditions 

11

EU directives 

11

H

Humidity 

11

I

Images 

6

storage 

6

Installation 

5

Instrument

moving 

9

overview 

1

Intended use 

1

Ionizer 

7

M

Mains Voltage 

11

Maintenance 

8

O

Overview 

1

P

Panthera Manager 

8

Physical dimensions 

11

Plate

Plate

 (continued)

capacity 

10

Plate barcodes 

10

Plate track 

6

Power consumption 

11

Power requirements 

11

Punch head 

6

Punch head module 

6

Punch sizes 

10

Punching 

6

Punching platform 

6

R

Routine maintenance 

8

S

Safety standards 

3

Sample barcodes 

10

Software 

13

Specifications 

10

Standards

safety 

3

Storage 

11

Symbols 

8

T

Temperatur

11

Touch screen 

7

Trademarks 

1

Transportation 

11

U

User instructions 

8

User interface 

8

W

WEEE 

14

17

Summary of Contents for 2081-0010

Page 1: ...2081 0010 INSTRUMENT MANUAL Panthera Puncher 9 Dried Blood Spot Punching Device ...

Page 2: ......

Page 3: ... 6 The touch screen 7 The ionizer 7 Disk detector 7 Information about user instructions and warnings 8 On screen 8 The User Manual 8 Routine maintenance 8 Decontamination 8 Symbols 8 Moving the instrument 9 Specifications 10 Capacity of plates 10 Punch sizes 10 Barcodes 10 Sample barcodes 10 Plate barcodes 10 Loading 10 Analytes 11 Physical dimensions 11 Power requirements 11 Environmental conditi...

Page 4: ...WEEE Instructions for PerkinElmer Products 14 Warranty 15 Index 17 ii ...

Page 5: ...ried blood spot deposits it to a microtiter plate and documents the traceability of the sample of the sample to the plate The instrument is semi automatic and intended for use by trained laboratory personnel Instrument overview The Panthera Puncher 9 is a semi automatic puncher for DBS and other similar samples that are dried on a filter paper media The instrument is equipped with a punch head and...

Page 6: ... mm 16 1 mm Alternatively 3 of the available plate positions may be occupied by deep well plates with max height 44 5 mm leaving 6 plate positions free for standard plates 1 Touch screen 2 Punching platform 3 Plate tray 4 Camera 5 Punch head assembly 6 Frame Panthera Puncher 9 Instrument Manual General information 2 ...

Page 7: ... your national authority The contact information for the manufacturer of this device to report a serious incident is Wallac Oy Mustionkatu 6 FI 20750 Turku Finland http www perkinelmer com Phone 358 2 2678 111 Warnings and precautions Please counsult the Warnings and precautions section in the Panthera Puncher 9 User Manual Warning Make sure the instrument is switched off before opening the side p...

Page 8: ... the wall and the back of the instrument The instrument must be connected to a mains supply having a protective earth Make sure the instrument is grounded A protective grounding screw marked with the ground symbol is located beside the power supply connector on the back of the instrument Panthera Puncher 9 Instrument Manual Safety information 4 ...

Page 9: ... Installation instructions are not included in this documentation because installation is only to be performed by personnel trained and authorized by PerkinElmer Panthera Puncher 9 Instrument Manual Installation instructions 5 ...

Page 10: ...The software analyses the sample card image and allows real time blood detection Together with the intelligent punching location algorithm it offers great benefits to the users the sample card blood spot is used in the most efficient way The camera is also able to read the barcode of the sample card in the punching area For Quality Assurance QA purposes the system can also save the camera blood ca...

Page 11: ...g operations the screen displays the camera image of the platform so that the user does not need to lean forward to see where the punch will be done The ionizer Under the punching platform there is an ionizer that reduces static electricity by releasing ions into the air Disk detector Dropping of the punched disk is verified with sensors in the lower end of the chute If a disk is not detected due ...

Page 12: ...ser Manual contains translations of the User Manual in pdf format Routine maintenance Routine maintenance comprises the tasks intended for performance by the user and these are described in the User Manual All other maintenance tasks must be performed by personnel trained and authorized by PerkinElmer Decontamination For the purpose of decontamination of the punch heads or other instrument parts c...

Page 13: ... moved we recommend that two people lift it by supporting the instrument from the lifting areas indicated in the image below Be careful not to tilt the puncher too much while moving it Rotated bottom view Panthera Puncher 9 Instrument Manual Moving the instrument 9 ...

Page 14: ...pported by the Panthera Puncher 9 Sample barcodes The following barcode types are supported Code 128 IL 2 5 Code 39 0 191 mm is the minimum bar width that can be used for barcodes The sample ID length has to be 2 20 characters By default the sample ID can contain numbers letters and special characters and Plate barcodes The following barcode types are supported Code 128 IL 2 5 0 191 mm is the mini...

Page 15: ...extraneous light can interfere with barcode reading Under such circumstances the lights of the Panthera Puncher 9 might need to be adjusted Operating temperature 15 30 ºC Relative humidity 20 80 for punches of 3 2 mm or greater 40 80 not condensed for 1 5 mm punches When operating at less than 20 relative humidity static electricity increases the probability of disks jumping out of the wells EMC E...

Page 16: ...The camera connector to be connected to one of the PC s USB ports The CAN IN connector to be connected to the PC s CAN port It allows the control of all mechanical parts by the software running on the computer The pedal connector to be connected to the optional external pedal The right side of the back panel hosts the mains inlet connector the grounding screw and the main power switch see picture ...

Page 17: ... Software DTKSOFT DTKBarReader dll uEye camera driver provided by IDS imaging Development Systems GmbH DSCameraDriver dll FPS On Screen virtual keyboard FPS Shared dll FPS VirtualKeyboard dll Panthera Puncher 9 Instrument Manual Specifications 13 ...

Page 18: ...ling and recovery programs vary by regulatory authority at your location Contact your local responsible body e g your laboratory manager or authorized representative for information regarding applicable disposal regulations Contact PerkinElmer at the website listed below for information specific to PerkinElmer products Website www perkinelmer com WEEE Europe follow the link provided above to acces...

Page 19: ... the Instrument Warranty Period whichever comes earlier Wallac warrants that this instrument is free from defects in materials and workmanship During the Instrument Warranty Period Wallac will provide parts and labor to repair defects in materials and workmanship Note The warranty on this instrument does not cover required Periodic Maintenance PM if any the cost and expense of which must be borne ...

Page 20: ...Panthera Puncher 9 Instrument Manual Warranty 16 ...

Page 21: ...zer 7 M Mains Voltage 11 Maintenance 8 O Overview 1 P Panthera Manager 8 Physical dimensions 11 Plate Plate continued capacity 10 Plate barcodes 10 Plate track 6 Power consumption 11 Power requirements 11 Punch head 6 Punch head module 6 Punch sizes 10 Punching 6 Punching platform 6 R Routine maintenance 8 S Safety standards 3 Sample barcodes 10 Software 13 Specifications 10 Standards safety 3 Sto...

Page 22: ...18 ...

Page 23: ......

Page 24: ...2081 9010 07 April 26 2022 Manufacturer Wallac Oy Mustionkatu 6 FI 20750 Turku Finland Tel 358 2 2678 111 Fax 358 2 2678 357 www perkinelmer com ...

Reviews: