background image

P/N 5500306-15 

 

Perle Fast Ethernet  

Media Converter 

Module 

 

 

Installation Guide 

 

 

C-100-XXXXX 

Unmanaged Module 

CM-100-XXXXX 

Managed Module 

 

Summary of Contents for C-100-M2LC2

Page 1: ...P N 5500306 15 Perle Fast Ethernet Media Converter Module Installation Guide C 100 XXXXX Unmanaged Module CM 100 XXXXX Managed Module...

Page 2: ...nformation on the management options of the CM 100 module refer to the MCR MGT Module User s Guide Model Connector Mode Distance Wavelength C 100 M2xx2 CM 100 M2xx2 SC ST LC MM 2 km 1 2 mi 1310 nm C 1...

Page 3: ...onverter Module into the chassis 5 Connect the fiber cable 6 Connect the copper cable Auto MDIX Jumper Note The factory settings for Auto MDIX will work for most installations but if there is a need t...

Page 4: ...en set to Auto the module will at power up check its internal flash memory to see if configuration information has been downloaded to it from a management module If so it will use this as its running...

Page 5: ...pper connection This will ensure the most optimal connection parameters will be in effect If the copper link partner does not support Auto negotiation the C 100 and CM 100 will default to 100 Mbps and...

Page 6: ...a direct copper connection Standard Mode In this mode the links on the fiber and copper sides can be brought up and down independently of each other A loss of link on either the fiber or copper port...

Page 7: ...h needs to be set Disabled The Media Converter Module will not monitor for or generate Far End Fault The following diagram is an illustration of the operation of this feature A Remote Media Converter...

Page 8: ...ch setting is provided so that the attached device near end can negotiate its Ethernet parameters as if it was negotiating directly with the far end device The Pause switch setting on the Media Conver...

Page 9: ...screwdriver remove the screw holding the face plate to the Chassis to reveal the slot opening 3 Set the jumpers and DIP switches on the Media Converter Module to the desired operating mode 4 Locate t...

Page 10: ...dule and gently pull the module out 2 If not inserting a replacement Media Converter Module cover the opened slot with a face plate and secure the screw Installing the Duplex Fiber Cable Locate a 100B...

Page 11: ...one Media Converter Module to another Media Converter switch fiber device Installing the Copper Cable Locate 100Base TX compliant copper cables with male RJ 45 connectors installed at both ends Conne...

Page 12: ...r Test On Power is on module operating normally Blinking slowly the module is in loopback mode Blinking quickly the module has a hardware error LKF Fiber Link Activity On Fiber link present Blinking q...

Page 13: ...nd automatically configures the connection Error Recovery In certain configurations and under specific conditions where the Media Converter Module brings down a link to convey status there is potentia...

Page 14: ...unable to get full connectivity with all DIP switches in the UP position these methods are recommended for troubleshooting Method 1 1 If the Module is a CM 100 set the Auto Config jumper J6 to SW so...

Page 15: ...verters should be lit Data should pass through the local converter over the fiber connection to the remote Media Converter At the remote Media Converter the data will be looped back and passed through...

Page 16: ...1310 Min 20 Max 12 Min 31 Max 14 11 C 100 M2LC2 CM 100 M2LC2 MM TX 1310 RX 1310 Min 20 Max 12 Min 30 Max 14 10 C 100 S2SC20 CM 100 S2SC20 SM TX 1310 RX 1310 Min 18 Max 7 Min 32 Max 3 14 C 100 S2ST20...

Page 17: ...32 Max 3 18 C 100 S1SC20D CM 100 S1SC20D SM TX 1550 RX 1310 Min 14 Max 8 Min 32 Max 3 18 C 100 S1SC40U CM 100 S1SC40U SM TX 1310 RX 1550 Min 8 Max 3 Min 33 Max 3 25 C 100 S1SC40D CM 100 S1SC40D SM TX...

Page 18: ...h case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio interferen...

Page 19: ...ttp www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Support Que...