Troubleshooting 

General 

 

Ensure the module is securely seated in the chassis. The 
PWR LED on the module should be on solid. 

 

Ensure both devices on either end of the fiber are compatible. 
If using a simplex fiber connection, ensure that you have both 
an Upstream (U) and Downstream (D) Media Converters. 

 

Ensure all cabling is of the correct type and is in good 
operating condition. 

 

For dual-stranded fiber connections, ensure the RX and TX 
has been reversed between the two Media Converters.  

No connectivity 

If unable to get full connectivity with all DIP switches in the UP 
position, these methods are recommended for troubleshooting. 

Method 1 

1.  If the Module is a CM-1000, set the Auto-Config jumper (J6) to 

SW so that switches are being read. 

2.  Turn off Fiber Negotiation (SW1 Down) on both Media 

Converters. Leave all other switches UP. 

3.  Connect the near end device to the copper connection. The 

LKC LED indicates good copper connection. If the LKC LED is 
not lit, then check the copper cable and the attached device. 
Repeat for the far end media converter. 

4.  Connect the fiber cable to both Media Converters.  The LKF 

LED indicates good fiber connection. If no LKF LED then 
check the fiber cabling. 

5.  Return media converter to the desired configuration. 

Method 2: 

The fiber connection can also be verified by configuring the remote 
Media Converter for loopback mode. The LKF LEDs on both 

Summary of Contents for CM-1000 Series

Page 1: ...P N 5500305 20 Perle Gigabit Media Converter Module Installation Guide C 1000 XXXXX Unmanaged Module CM 1000 XXXXX Managed Module C 1000 SFP Unmanaged Module CM 1000 SFP Managed Module...

Page 2: ...ment options of the CM 1000 module refer to the MCR MGT Module User s Guide Model Connector xx Mode Distance Wavelength TX RX C 1000 M2xx05 CM 1000 M2xx05 SC ST LC MM 550 m 1804 ft 850 850 nm C 1000 M...

Page 3: ...C SM 120 km 74 6mi 1550 1550 nm C 1000 S1SC120U CM 1000 S1SC120U SC SM 120 km 74 6 mi 1510 1590 nm C 1000 S1SC120D CM 1000 S1SC120D SC SM 120 km 74 6 mi 1590 1510 nm C 1000 S2xx160 CM 1000 S2xx160 SC...

Page 4: ...fig Jumper CM 1000 only The Auto Config jumper J6 is located on the upper edge at the midpoint of the module Refer to the diagram below for labelling Strapping pins 1 and 2 of the jumper will set the...

Page 5: ...connection parameters will be in effect If connecting to another Perle Gigabit Media Converter this parameter should be set to Auto Off Fiber Negotiation should only be turned off if the fiber link p...

Page 6: ...nk is lost on one of the connections then the other link will be brought down If the installation has a Media Converter on both ends of the fiber link and both are setup for Smart Link Pass Through a...

Page 7: ...urn cause the transmit fiber link to be brought down Note This feature only takes effect if Fiber Negotiation has been turned OFF The following diagram is an illustration of the operation of this feat...

Page 8: ...as if it was negotiating directly with the far end device These parameters on the Media Converter Module should match those of the far end device Pause Switch 5 Switch Position Mode Up default Enable...

Page 9: ...d The loopback feature is disabled This is the normal position for regular operation The switch must be set to this position in order for data to pass through the Media Converter Module Enabled This i...

Page 10: ...rom its packaging 2 Using a cross head screwdriver remove the screw holding the face plate to the Chassis to reveal the slot opening 3 Set the jumpers and DIP switches on the Media Converter Module to...

Page 11: ...opening slot with a face plate and secure the screw Installing the SFP Fiber Module C 1000 SFP and CM 1000 SFP require an SFP fiber module 1 Locate appropriate fiber module and insert into opening 2...

Page 12: ...le from one Converter to the other Converter switch fiber device Installing the Copper Cable Locate 1000Base TX compliant copper cables with male RJ 45 connectors installed at both ends Connect the RJ...

Page 13: ...ng slowly the module is in loopback mode Blinking quickly the module has a hardware error LKF Fiber Link Activity On Fiber link present Blinking quickly Fiber link present and receiving data Blinking...

Page 14: ...t through or crossover and automatically configures the connection The Media Converter Module can also correct for wires swapped within a pair Error Recovery In certain configurations and under specif...

Page 15: ...n the UP position these methods are recommended for troubleshooting Method 1 1 If the Module is a CM 1000 set the Auto Config jumper J6 to SW so that switches are being read 2 Turn off Fiber Negotiati...

Page 16: ...verter over the fiber connection to the remote converter At the remote converter the data will be looped back and passed through the fiber once again to pass through the local converter to the copper...

Page 17: ...M 1000 M2xx05 SM TX 850 RX 850 Min 9 5 Max 3 Min 17 Max 3 7 5 C 1000 M2xx2 CM 1000 M2xx2 MM TX 1310 RX 1310 Min 6 Max 0 Min 17 Max 3 11 C 1000 S2xx10 CM 1000 S2xx10 SM TX 1310 RX 1310 Min 9 5 Max 3 Mi...

Page 18: ...9 32 C 1000 S1SC120U CM 1000 S1SC120U SM TX 1510 RX 1590 Min 3 Max 2 Min 34 Max 9 31 C 1000 S1SC120D CM 1000 S1SC120D SM TX 1590 RX 1510 Min 3 Max 2 Min 34 Max 9 31 C 1000 S2xx160 CM 1000 S2xx160 SM T...

Page 19: ...ch case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio interfere...

Page 20: ...at http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Support...

Reviews: