This document contains instructions necessary for the installation 
and operation of the Perle Fast Ethernet Fiber to Fiber Media 
Converter Module(s) (C-100MM and CM-100MM) that are used in 
conjunction with a Perle MCR chassis. The C-100MM are the 
unmanaged media converter modules, and the CM-100MM are 
the managed versions. These products allow dissimilar 100Base-X 
fiber interfaces to connect to each other. 

These are the fiber to fiber conversion models: 

 

Multimode to Multimode   (MM) 

 

Multimode to Single Mode  (SM) 

 

Multimode to Single Mode Single Strand  (SM) 

These media converter modules operate over different 
wavelengths and distances, depending on the model selected 
(See tables below). For information on the management options of 
the CM-100MM converter module, refer to the MCR-MGT Module 
User’s Guide. 

Fiber port 1 – MM1 

Model 

 

Connector

 

Mode  

 

Distance

  

Wavelength 
(TX/RX)

 

All models 

SC/ST/LC 

MM. 

2 km/1.2 mi. 

1310 nm 

Fiber port 2 – MM2/SM2 

Model 

 

Connector

 

Mode  

 

Distance

  

Wavelength 
(TX/RX)

 

C-100MM-M2xx2 
CM-100MM-M2xx2 

SC/ST/LC 

MM 

2 km/1.2 mi. 

1310 nm 

C-100MM-S2xx20 
CM-100MM-S2xx20 

SC/ST/LC 

SM 

20 km/12.4 mi 

1310 nm 

C-100MM-S2xx40 
CM-100MM-S2xx40 

SC/ST/LC 

SM 

40 km/24.9 mi 

1310 nm 

C-100MM-S2xx80 
CM-100MM-S2xx80 

SC/ST/LC 

SM 

80 km/49.7 mi 

1550 nm 

C-100MM-S2xx120 
CM-100MM-S2xx120 

SC/ST/LC 

SM 

120 km/74.6mi 

1550 nm 

C-100MM-S1SC20U 
CM-100MM-S1SC20U 

SC 

SM 

20 km/12.4 mi. 

1310/1550 nm 

Summary of Contents for CM-100MM Series

Page 1: ...P N 5500313 10 Perle Fast Ethernet Fiber to Fiber Media Converter Module Installation Guide C 100MM XXXXX Unmanaged Module CM 100MM XXXXX Managed Module...

Page 2: ...d SM These media converter modules operate over different wavelengths and distances depending on the model selected See tables below For information on the management options of the CM 100MM converter...

Page 3: ...D SC SM 20 km 12 4 mi 1550 1310 nm C 100MM S1SC40U CM 100MM S1SC40U SC SM 40 km 24 9 mi 1550 1310 nm C 100MM S1SC40D CM 100MM S1SC40D SC SM 40 km 24 9 mi 1550 1310 nm Note Please refer to Perle s web...

Page 4: ...5 Refer to the diagram below for labelling This jumper only applies to the CM 100MM converter module Auto Pin 2 and Pin 3 are strapped When set to Auto At power up the media module will check its inte...

Page 5: ...Position Mode Up default Link Pass Through Mode Down Standard Mode Link Pass Through In this mode the link state on one fiber connection is directly reflected through the media module to the other fib...

Page 6: ...iber link to the remote end module This in effect notifies the fiber link partner that an error condition exists on the fiber connection Note This switch needs to be set to either generate or detect t...

Page 7: ...must be set to this position in order for data to pass through the media module Enabled This is a test mode All data received on the receive RX fiber connection is looped back to the transmit TX fiber...

Page 8: ...veal the slot opening Set the jumpers and DIP switches on the media module to the desired operating mode optional Locate the top and bottom alignment guides inside the MCR chassis Using the module ali...

Page 9: ...ew Installing the Duplex Fiber Cable Locate a 100Base X compliant duplex 2 strands fiber cable with the appropriate connectors Connect the fiber cables from the media module to the other media module...

Page 10: ...Test On Power is on the module is operating normally Blinking slowly the module is in loopback mode Blinking quickly the module has a hardware error LK1 MM1 Fiber Link 1 Activity On Fiber link presen...

Page 11: ...ng Note If troubleshooting a CM 100 setting the Auto Config jumper J5 to SW will ensure the DIP switches are being read Method 1 1 Set the Link mode to Standard SW1 Down on both media converter module...

Page 12: ...03 mm by 38 mm by 152 mm 8 in By 1 5 in by 6 in Fiber Optic Specifications Fiber port 1 MM1 Model Mode Wave length nm TX Power dB RX Power dB Budget dB C 100MM M2SC2 CM 100MM M2SC2 MM TX 1310 RX 1310...

Page 13: ...M S2LC80 SM TX 1550 RX 1550 Min 5 Max 0 Min 34 Max 3 29 C 100MM S2SC120 CM 100MM S2SC120 SM TX 1550 RX 1550 Min 0 Max 5 Min 35 Max 3 35 C 100MM S2ST120 CM 100MM S2ST120 SM TX 1550 RX 1550 Min 0 Max 5...

Page 14: ...n which case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio inte...

Page 15: ...d at http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Suppo...

Reviews: