background image

 

 

Perle 10/100/1000 Media Converter Module – Installation Guide

   

10

Loopback (Switch 7) 

Switch Position 

Mode 

Up (default) 

Disabled 

Down 

Enabled 

Disabled: This is the setting for normal operation. The switch 
must be set to this position in order for data to pass through the 
Media Converter Module. 

Enabled: This is a test mode. All data received on the receive 
(RX) fiber connection is looped back to the transmit (TX) fiber 
connection.  The state of the copper link is not relevant since no 
data is passed through to the copper side. This mode will override 
all other switch settings. 

Installing or Replacing Media 
Converter Modules 

Caution: Observe electrostatic discharge precautions when 
installing the Media Converter Module(s) into the Chassis. Failure 
to observe this caution could result in damage to the Media 
Converter Module(s) and /or chassis. 

The Perle Media Converter Modules can be installed in any 
available slot and in any order within the chassis. 

1.  Remove the Media Converter Module from its packaging.  

2.  Using a cross-head screwdriver, remove the screw holding the 

face plate to the Chassis to reveal the slot opening. 

3.  Set the jumpers and DIP switches on the Media Converter 

Module to the desired operating mode. 

4.  Locate the top and bottom alignment guides inside the 

Chassis. 

5.  Using the module alignment guides gently slide the module 

into the slot until it becomes flush with the front of the Chassis. 
Light pressure may be needed to seat the module. Do not 
force the module as you might cause some damage. If there is 
resistance, remove the module, check the module connector 
for damaged or incorrectly aligned pins, if there is no damage, 
retry to insert the module. 

Summary of Contents for CM-1110-SFP

Page 1: ...P N 5500308 20 Perle 10 100 1000 Ethernet Media Converter Module Installation Guide C 1110 XXXXX Unmanaged Module CM 1110 XXXXX Managed Module C 1110 SFP Unmanaged Module CM 1110 SFP Managed Module...

Page 2: ...able below Model Connector xx Mode Distance Wavelength C 1110 M2xx05 CM 1110 M2xx05 SC ST LC MM 550 m 1804 ft 850 850 nm C 1110 M2xx2 CM 1110 M2xx2 SC ST LC MM 2 km 1 2 mi 1310 1310 nm C 1110 S2xx10 C...

Page 3: ...10 S2xx40 SC ST LC SM 40 km 25 mi 1310 1310 nm C 1110 S1SC40U CM 1110 S1SC40U SC SM 40 km 25 mi 1310 1490 nm C 1110 S1SC40D CM 1110 S1SC40D SC SM 40 km 25 mi 1490 1310 nm C 1110 S2xx70 CM 1110 S2xx70...

Page 4: ...1110 only optional 4 Set the DIP switch settings optional 5 Insert the Media Converter Module into the chassis 6 Connect the copper cable 7 Connect the fiber cable Auto MDIX Jumper Note The factory se...

Page 5: ...en set to Auto the module will at power up check its internal flash memory to see if configuration information has been downloaded to it from a management module If so it will use this as its running...

Page 6: ...o 10 or 100 Mbps and force Half Duplex mode as per IEEE specifications Off When the Auto Negotiation switch is set to the OFF position the Media Converter Module will not negotiate the Ethernet parame...

Page 7: ...l This in effect notifies the fiber link partner that an error condition exists on the fiber connection If the remote Media Converter is set up for Fiber Fault Alert FFA and the local Media Converter...

Page 8: ...ction on its receiver A Disables fiber transmitter B Detects loss of link on its fiber receiver B Drops link on copper connection because Smart Link Pass Through is configured A Link on copper connect...

Page 9: ...r will negotiate Ethernet parameters on the fiber connection This will ensure that the most optimal connection parameters will be in effect If connecting to another Perle Media Converter this paramete...

Page 10: ...Failure to observe this caution could result in damage to the Media Converter Module s and or chassis The Perle Media Converter Modules can be installed in any available slot and in any order within t...

Page 11: ...t with a face plate and secure the screw Installing the SFP Fiber Module 1 C 1110 SFP and CM 1110 SFP require an SFP fiber module Locate appropriate fiber module and insert into opening 2 Ensure the S...

Page 12: ...ter Module to the other Media Converter switch fiber device Installing the Copper Cable 1 Locate 10 100 1000Base T compliant copper cables with male RJ 45 connectors installed at both ends 2 Connect t...

Page 13: ...x Mode Off Half Duplex Mode LKF fiber On Fiber link is present Off No fiber link present Blinking slow Copper link down but fiber link appears functional Blinking fast Fiber link is up and receiving d...

Page 14: ...re the Media Converter Module brings down a link to convey status there is potential for a deadlock Recovery is achieved by momentarily restoring the link to see if the original failure has been resol...

Page 15: ...DIP switches are being read 2 Set the Link mode to Standard SW2 Down on both Media Converters Leave all other switches in the Up position 3 Connect the near end device to the copper connection The LKC...

Page 16: ...ower dB RX Power dB Budget dB C 1110 M2xx05 CM 1110 M2xx05 MM TX 850 RX 850 Min 9 5 Max 4 Min 17 Max 3 7 5 C 1110 M2xx2 CM 1110 M2xx2 MM TX 1310 RX 1310 Min 6 Max 0 Min 17 Max 3 11 C 1110 S2xx10 CM 11...

Page 17: ...0 RX 1550 Min 0 Max 5 Min 23 Max 3 23 C 1110 S1SC80U CM 1110 S1SC80U SM TX 1510 RX 1590 Min 2 Max 3 Min 26 Max 3 24 C 1110 S1SC80D CM 1110 S1SC80D SM TX 1590 RX 1510 Min 2 Max 3 Min 23 Max 3 14 C 1110...

Page 18: ...e harmful interference in which case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this prod...

Page 19: ...at http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Suppor...

Reviews: