I/O Commands
188
IOLAN Device Server User’s Guide, Version 1.8
trigger-level
Specify the value that will trigger an alarm, the measurement is based on the
Type
and
Range
that you specify. This value must not fall within the scope of the value used to
clear an alarm.
clear-mode
Specifies whether an activated alarm must be
Manually
cleared, or can be cleared when
the input drops below the specified value (when
Trigger Type
is
High
) or goes above
the specified value (when
Trigger Type
is
Low
).
clear-level
Specify that value that will clear an alarm, the measurement is based on the
Type
and
Range
that you specify. This value must not fall within the scope of the value used to
trigger an alarm.
snmp
Sends an SNMP trap when an alarm is triggered or cleared. The trap consists of the
severity level and whether the alarm was triggered or cleared.
syslog
Sends a message to syslog when an alarm is triggered or cleared. The syslog entry
includes the severity level and the value that caused the alarm to trigger or clear. The
syslog message is associated with
Level Critical
.
Summary of Contents for IOAN DS1
Page 1: ...IOLAN DS Family DS1 TS2 User s Guide Version 1 8 Part 5500162 18 November 2006...
Page 18: ...Table of Contents 18 IOLAN Device Server User s Guide Version 1 8...
Page 50: ...EIA 232 Cabling Diagrams 50 IOLAN Device Server User s Guide Version 1 8...
Page 194: ...I O Commands 194 IOLAN Device Server User s Guide Version 1 8...
Page 202: ...API I O Access Over TruePort 202 IOLAN Device Server User s Guide Version 1 8...
Page 210: ...Glossary 210 IOLAN Device Server User s Guide Version 1 8...
Page 214: ...Index 214 IOLAN Device Server User s Guide Version 1 8...