background image

Rev 1.0                                                                    Cod. 00.008.565 

MENU STRUCTURE 

 

 
 
 
Push 

OK/SBY 

and then the

 

SET 

button to enter the 

programming menu. 
Navigate within the menu by 
pressing 

SET

  and enter the 

sub-menu to modify the 
parameters by pressing  

OK / SBY.

 

 
PROGRAMMING THE PARAMETERS 

 

 

 
Once  you  enter  the  menu,  change  the 
parameters 

nA, 

tA, 

FL 

pressing 

OK/SBY

  button  and  then  select  the 

desidered  value  by 

SET

  button  and 

confirm it  by pressing 

OK/SBY

.  

 
Exit  the  programming  confirming  the 
value  of  the  percentuage  flow  rate  (FL) 
by pressing  

OK/SBY

.  

 

The programmable Values are:

  

nA

  =  1-24;  number  of  daily  dosings  (1 

dosing every hour)  
 

tA

  =  1-99  minutes;  total  daily  dosing 

time  
 

FL

  =  10%  -  FS  (Full  Speed  =  100%), 

percentuage    of  the  maximum  flow  of 
the pump. 
 

 

DISPLAYING THE PROGRAMMED PARAMETERS 

 

   

 

 

   

 

 

 

 
 
 
 
 
 
 
During normal operation of the pump it is possible to display the programmed 
parameters by pressing the 

SET 

button.  

The dosing stops and the pump displays subsequently:  
 
-nA and the programmed number of dosings  
-tA and the programmed total minutes of daily dosing  
-FL and the programmed percentuage of the flow rate.  
 
Remember that FS means Full Speed =  100% = maximum flow rate  
 
 
 
 
 

Summary of Contents for MP2-POOL-T

Page 1: ...MANUALE DI PROGRAMMAZIONE IT PROGRAMMING INSTRUCTIONS UK MANUEL DE R GLAGE FR MANUAL DE REGULATI N ES MP2 POOL T...

Page 2: ...o dosaggio giornaliero Descrizione del funzionamento con i parametri di fabbrica Al ricevimento dell enable pompa di ricircolo attiva la pompa attende 30 minuti ritardo di attivazione prima di dosare...

Page 3: ...pa riceve il segnale di enable la pompa passa nello stato di delay ovvero ritardo In questo stato la pompa visualizza dE attende 30 minuti prima di passare alla fase di dosaggio La pompa controlla cos...

Page 4: ...mazione confermando il valore della portata percentuale FL Valori programmabili nA 1 24 dosaggi giornalieri 1 dosaggio ogni ora tA 1 99 minuti tempo totale di dosaggio giornaliero FL 10 FS 100 Full Sp...

Page 5: ...st daily dosing Description of the default pump functioning After the receiving of the enable input recirculation pump is swiched on the pump waits 30 minutes delay start before the first daily dosing...

Page 6: ...e enable signal the pump passes in the state of delay In delay state the displayshows dE the pump waits 30 minutes before moving to the dosing phase The pump continuously checks the presence of the en...

Page 7: ...e of the percentuage flow rate FL by pressing OK SBY The programmable Values are nA 1 24 number of daily dosings 1 dosing every hour tA 1 99 minutes total daily dosing time FL 10 FS Full Speed 100 per...

Page 8: ...ntement avant la premi re dose quotidienne Description de l op ration avec les param tres d usine D s r ception du consentement pompe de circulation actif la pompe attend 30 minutes retard de allumage...

Page 9: ...t vous pouvez effectuer la programmation des parameters et l amor age Au moment o la pompe re oit le signal de consentement au dosage la pompe passe l tat de retard delay Dans cet tat la pompe Affiche...

Page 10: ...BY Vous pouvez quitter la programmation confirmant la valeur du d bit FL Valeurs programmables nA 1 24 doses quotidiennes une dose par heure tA 1 99 minutes temps total du dosage quotidien FL 10 FS 10...

Page 11: ...de habilitaci n de dosaje bomba de circulaci n encendida la bomba espera 30 minutos retardo de activaci n inicio tard o antes de dosificar Pasado estos 30 minutos la bomba dosificar 8 veces nA durant...

Page 12: ...modificar los par metros y puede hacier el cebado En el momento en el que la bomba recibe la se al de habilitaci n la bomba pasa en el estado de DELAY o retraso En este estado la bomba Muestra dE Esp...

Page 13: ...uede salir de la programaci n confirmando el valor del caudal FL Valores programables nA 1 24 dosis diarias 1 dosis cada hora TA 1 99 minutos dosis diaria total FL 10 FS Full Speed 100 porcentual del...

Page 14: ...Rev 1 0 Cod 00 008 565 14 NOTE...

Page 15: ...Rev 1 0 Cod 00 008 565 15...

Page 16: ...Rev 1 0 Cod 00 008 565 16 PERLE...

Reviews: