Event Logs
39
* Unable to bind UDP Boot P server port
Generated as a result of an internal device error. Try resetting the device. If this is unsuccessful, contact a service
representative.
* Unable to bind UDP DHCP server port
Generated as a result of an internal device error. Try resetting the device. If this is unsuccessful, contact a
service representative.
* Unable to route!! UDP failure
Generated when the device tried to open an already open UDP channel, causing IP routing to fail.
* Unknown call type on remote site <remote site alias>
The attempted call is not an ISDN or PPP leased line call. Possible cause is a remote site profile being deleted while a
connection attempt is being made.
* WWW (HTTP) server removed from firewall
The IP address of the WWW (HTTP) server removed from the table of services available through the firewall.
* WWW (HTTP) server added to firewall
The IP address of the Telnet WWW (HTTP) added to the table of services available through the firewall.
* X count overflow. Reset to history size
Generated when the number of items logged exceeds the space available. X = “ALARM” or “EVENT”