background image

© 2008

1

24" C-Series Operation / Installation Manual

INTRODUCTION

Congratulations on your purchase of a Perlick residential refrigeration
product. Celebrating over 90 years of excellence, Perlick is the industry
leader in commercial refrigeration systems. Today, Perlick has taken its
expertise and experience into creating the highest quality and most inno-
vative residential products on the market. Perlick’s product offering gives
you the opportunity to enjoy the functionality and user friendliness in just
about any room of your home, including kitchens, bedrooms, entertain-
ment rooms, basements and even bathrooms. All Perlick products are
built with commercial-grade stainless steel – providing you with the
beauty and durability for a lifetime of use.

This Installation and Operation manual will answer your questions about
the features, operation and maintenance of your Perlick unit. If you have
questions that are not addressed here, call 800/558-5592. 

IMPORTANT:

Please read all instructions completely before attempting

to install or operate the unit. Take note of DANGER, CAUTION and WARN-
ING when they appear in the manual. This information is important for the
safe and efficient installation, operation and care of your Perlick unit.

DANGER indicates a hazard that will result in serious injury or
death if precautions are not followed.

WARNING indicates a hazard may cause serious injury or
death if precautions are not followed.

CAUTION indicates a hazard where minor injury or product
damage may occur if you do not follow instructions.

WARRANTY REGISTRATION

To request information or service, the model number and serial number
must be provided. This information is located on the inside ceiling of the
unit and on the warranty registration card included with information pack-
et shipped with the unit. 

IMPORTANT:

Read through the included warranty statement then com-

plete and mail the Warranty Registration Card as soon as possible to val-
idate the registration date. Warranty registration can also be done online
at 

www.bringperlickhome.com

. If warranty registration is not completed,

Perlick will use the date of sale as the first date of warranty for the unit.
Please record the purchase date of the unit and the dealer’s name, address
and telephone number below.

Model Number

_____________________________________

Serial Number

_____________________________________

Purchase Date

_____________________________________

Dealer Name

_____________________________________

Dealer Address

_____________________________________

Dealer Phone No. _____________________________________

Retain this manual along with the sales receipt for future reference.

TABLE OF CONTENTS

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

Warranty Registration  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

General Precautions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Installation Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Preparing the Space  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Preparing Electrical Connections  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Unpacking and Moving the Unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Anti-Tip Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Shelving  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Door Panel Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Wood Overlay Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Wooden Wine Rack Trim Finishing  . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

General  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Interior Light  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Loading Product  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Temperature Control  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Checking Product Temperature  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Cleaning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Cleaning the Condenser  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Summary of Contents for 24" C-Series

Page 1: ...Installation Operation Manual 24 C Series Refrigerator Wine Reserve Beverage Center ...

Page 2: ...uct damage may occur if you do not follow instructions WARRANTY REGISTRATION To request information or service the model number and serial number must be provided This information is located on the inside ceiling of the unit and on the warranty registration card included with information pack et shipped with the unit IMPORTANT Read through the included warranty statement then com plete and mail th...

Page 3: ... front louvered toe plate is free of obstruction Obstructing free air flow can cause unit to malfunction and may void the warranty CAUTION Use only Perlick replacement parts Imitation parts can dam age the unit and may void the warranty INSTALLATION SPECIFICATIONS General All electrical instructions assume that outlet is located 4 10 inches from the floor Floor must be level in area of installatio...

Page 4: ...cordance with applicable electrical codes DANGER Failure to comply with the above electrical guidelines may result in possible injury death fire or loss of property UNPACKING AND MOVING THE UNIT CAUTION Do not cut cardboard sleeve covering the unit Cutting may result in damage to the exterior of the unit 1 Uncrate the unit outside on a flat level surface Remove the cardboard sleeve by removing the...

Page 5: ... opening 2 Check that the following are level and square front face and interior opening installation opening and floor surface countertop bottom front edge I IM MP PO OR RT TA AN NT T The floor under the unit must be at the same level as the surrounding finished floor 3 If all surfaces are level refer to Figure 3 and perform the following a Measure from the floor to the bottom of the front edge o...

Page 6: ...l hook 4 Repeat for other bracket s 5 Push extenders completely into the unit Align the shelf grooves with the extenders and slide completely into the unit DOOR PANEL OPTIONS Perlick residential units offer a variety of door panel design alternatives solid stainless steel solid wood overlay stainless steel glass and wood overlay glass Solid stainless steel and stainless steel glass doors are shipp...

Page 7: ...crew Lockwasher Lock strike Nut Lock bracket Lock body Figure 7 Glass Wood Overlay Door Panel Figure 6 Door Lock Optional WOOD OVERLAY INSTALLATION Before beginning installation check all components for proper fit and fin ish WARNING All overlay doors require a trim panel at least 3 4 thick The solid wood overlay panel should not weigh more than 20 pounds The glass wood overlay panel should not we...

Page 8: ... overlay door should be mounted on overlay panel only not the door to avoid damage to the fac tory door 1 Handle must be attached to overlay before mounting overlay onto door Mark rear of wood overlay panel with handle fastening loca tions 2 Drill through wood overlay panel at marked locations taking care not to damage the wood overlay panel 3 Countersink screw heads so screw heads are flush with ...

Page 9: ... manual switch is left on for an extended period of time it may increase the cabi net temperature especially at the top and cause the refrigeration system to run longer Loading Product I IM MP PO OR RT TA AN NT T Before storing perishables allow unit to run for a minimum of 24 hours to allow temperature stabilization after start up When loading items into unit do not block internal louvers and fan...

Page 10: ...ght or near a heat source MAINTENANCE WARNING Shut off the electricity to the unit before cleaning the con denser and other routing maintenance Cleaning To clean stainless steel exterior or interior surfaces use a soft non abra sive stainless steel cleaner to wipe down the surfaces Glass doors can be cleaned using any standard glass cleaner available on the market To clean interior non metallic su...

Page 11: ...g circuit breaker or fuse on Is the control set properly Is the condenser area clean The refrigerated compartment is warmer than usual Is the control set properly Is the light staying on Is the condenser area clean and free of obstruction Has the door been open for a long time or more frequent door openings occurred Are the internal louvers and fan guard openings obstructed The refrigerated compar...

Page 12: ...rtment 8300 W Good Hope Road Milwaukee WI 53223 E mail us at warrantyserv perlick com To obtain product service replacement parts or accessories Use only genuine Perlick replacement parts and accessories Genuine Perlick parts and accessories are designed to work correctly with Perlick prod ucts and offer superior service life The use of non Perlick parts can damage the unit and may void the warran...

Page 13: ... home during normal business hours This warranty applies only to products installed for normal residential use it does not include adjusting the controls door reversal light bulb or clean ing the condenser This warranty is extended only to the original purchaser of the Perlick product The above warranty does not apply if Failure of product was due to transportation Product was improperly installed...

Page 14: ... 1 800 558 5592 Fax 414 353 7069 www bringperlickhome com Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without warning 2008 24 C Series Installation Operation Manual Document No Z2303 ...

Reviews: