Column Refrigeration Service Manual
82
8.10 Replace Door Handle
To replace the door handle:
1. Remove the door trim cover at the top of the
door by removing the two fasteners.
See figure 8-9.
2. Remove the overlay from the door
(see
Overlay Panel Installation and
Adjustments
-
).
3. Remove the four (4) fasteners holding the
handle to the overlay (never over-tighten the
handle mounting fasteners as this could deform
the overlay panel).
Figure 8-9. Removing door trim cover.