Installation and Tapping – 

Concessionaire Dispensers

Connecting the Regulator to the 
CO

2

Cylinder

Remove blue plug from regulator fitting. 
(Note: Do not remove the carbonic washer).

Screw regulator onto gas cylinder valve. Tighten
with wrench until vertically straight. Be sure that 
shut-off valve (black lever) on regulator is in 
the OFF (horizontal) position.

Place a screw clamp over end of red air line 
and push onto regulator tailpiece. Tighten clamp
with a screwdriver.

Adjusting the CO

2

Gas Flow 

Turn regulator adjusting screw counterclockwise
until it turns freely.

Turn hand valve counterclockwise on CO

2

cylinder to the fully open position.

Turn regulator adjusting screw clockwise until 
desired pressure is reached (approximately 
12-15 lbs.). Tighten stop nut on adjusting screw.

Open shut-off valve on bottom of regulator.

CO

2

Leak Test

Dilute a small amount of liquid dishwashing soap
and rub the soapy mixture around each connection.
If bubbles appear, tighten connection.

Replacing CO

2

Gas Cylinder

Turn CO

2

hand valve clockwise until seated and

close shut-off valve on regulator.

Unscrew regulator from cylinder fitting.

Replace carbonic washer (Part No. 157F2P), 
if needed and reattach regulator to filled 
cylinder.

Turn CO

2

hand valve counterclockwise until 

fully open. Turn regulator shut-off valve to 
open position.

Adjust CO

2

gas flow as required, turning

clock wise for higher pressure.

Proper CO

2

Handling

ALWAYS

...

Connect a regulator (reducing valve) to 
CO

2

cylinder.

Secure cylinder in upright position whether in 
storage or in use.

Keep cylinder away from heat. Rupture disc 
vents at 122° F. maximum.

Ventilate room after high pressure gas leakage.

Check the last DOT test date on cylinder neck 
before filling. If more than five years old, the 
cylinder must be retested to DOT specifications.

Be sure CO

2

cylinder outlet fitting is free of dust 

or dirt before attaching regulator.

Store CO

2

cylinder and regulator assembly 

upright.

Allow only properly trained and experienced 
personnel to handle high pressure gas. 

NEVER

...

Connect cylinder directly to a keg without a 
regulator (reducing valve).

Drop or throw regulator or CO

2

cylinder.

Transport CO

cylinder in a closed vehicle.

Apply oil to a regulator. 

Shut off CO

cylinder when not in use. You will 

not save gas by doing so!

Allow untrained, inexperienced personnel to 
handle high pressure gas.

Failure to heed this warning could result in 
personal injury or death.

CO2
PRESSURE
GAUGE

CO2 
GAS 
DRUM

REGULATOR
FITTING

REGULATOR
ADJUSTING
SCREW

FITTING FOR
RED AIR HOSE

SHUT-OFF VALVE
(BLACK LEVER IN
CLOSED POSITION)

HAND
VALVE

PERLICK

PSI

10

50

0

60

20

40

30

WARNING/SAFETY INSTRUCTIONS

Beverage systems pressur-
ized with carbon dioxide or
nitrogen must be equipped
with two safety relief
valves; one at the cylinder
regulator and the other in
the gas line upstream on
the product tanks.

Summary of Contents for DC Series

Page 1: ...rlick com MODEL NOS DC Series IMPORTANT INFORMATION Complete the enclosed warranty card and mail to the Perlick Corporation to register the warranty If the card is not returned the warranty period will begin from the date the equipment is shipped from the factory This manual has been prepared to assist you in the installation of your Concessionaire Dispenser and to acquaint you with its operation ...

Page 2: ...nless steel drainer overflow tank two drain valves with garden hose fittings for cabinet floor drain and overflow tank and 20 lb CO2 drum holder Front compartment provides storage for cups or other non refrigerated items REFRIGERATION R 134a capillary tube type Aluminum fin and copper tube evaporator coil Forced air into dispensing head Adjustable temperature control Self defrosting Pull out conde...

Page 3: ...om so that caster is centered over cabinet seam Use supplied 1 4 20 x 3 4 hex head self tapping machine screws Plumbing None required Garden hose connections for dumping liquid wastes Electrical The cabinet must be connected to a separately fused power source see electrical specification plate and grounded in accordance with National and Local Electrical Codes Caution Do not attempt to operate the...

Page 4: ... beer line connector hose and thread onto top of keg coupler Hand tighten Place clamp on one end of red air line Push end over air valve located inside cabinet Tighten clamp with screwdriver Turn shut off valve to OFF horizontal position Place clamp on the other end of red air line and push over tailpiece on coupler Tighten clamp with screwdriver CAUTION Do not use keg coupler as a handle to lift ...

Page 5: ...ounterclockwise until fully open Turn regulator shut off valve to open position Adjust CO2 gas flow as required turning clock wise for higher pressure Proper CO2 Handling ALWAYS Connect a regulator reducing valve to CO2 cylinder Secure cylinder in upright position whether in storage or in use Keep cylinder away from heat Rupture disc vents at 122 F maximum Ventilate room after high pressure gas le...

Page 6: ...to automatically maintain a storage temperature of 36 41 degrees F The control is factory set at 38 degrees F Adjusting the temperature The temperature control is inside the cabinet on the right hand side of the evaporator fan panel assembly You will need a screwdriver to turn the adjusting screw Make small adjustments until the desired temperature is achieved Colder Temperatures Turn the adjustin...

Page 7: ...ate bacterial growth Yeast All domestic draft beers contain a small amount of yeast which remains in the beer from the fermentation process When the temperature of draft beer exceeds 50 a process of secondary fermentation may take place The beer faucet may exhibit a white colored substance yeast build up if not cleaned on a regular basis Beer Stone All beer contains calcium which is present from t...

Page 8: ...h a clean glass Place the glass at a 45 angle one inch below faucet Do not let the glass touch the faucet Open the faucet all the way STEP 1 Let the remaining beer run straight down the middle of the glass This ensures proper release of CO2 by producing a 3 4 to 1 foam head STEP 3 After the glass has reached half full gradually bring the glass to the upright position STEP 2 Close the faucet quickl...

Page 9: ...e is too low due to leak or pressure setting CO2 is turned off at night Cooler is too cold CO2 leak or defective sticking check valve Sluggish CO2 regulator Cloudy Beer Beer in glass appears hazy not clear CAUSES Dirty glass Dirty faucet or beer line Frozen or nearly frozen beer Old beer Beer that has not been refrigerated for a long period of time Beer and CO2 Facts Keg No of No of No of No of Fu...

Page 10: ...door models 1 4 h p condensing unit 115 volt 60 hz C22647 N A N A Condensing unit model UFI10HBX 515301063 N A N A Compressor model FFI10HBX 513200314 N A N A Fan Motor Assembly 215315009 N A N A Condenser coil 15352019 N A N A Terminal board 219101538 N A N A Overload protector MRT20AGK5590 N A N A Relay 21351619 N A N A Capacitor 282 339 MFD 155V 13556529 N A N A Coil assembly 2 door SC BB 62210...

Page 11: ...ler Series D Item Part No No Description 1 26000D Single valve keg coupler 2 C14316 O ring 3 31080 2P Ball check 4 31089 2P O ring 3 per assembly 5 31088 2P Bottom seal washer 6 31087 2P Probe washer domestic 7 157R2P Coupling Gasket 8 23682 2P Check valve Miscellaneous Part No Description 157L2P Beer line connector gasket 57F2P CO2 tank washer 1392R Red air hose 529 Beer hose 2928D Twin gauge CO2...

Page 12: ...3 Phone 414 353 7060 Fax 414 353 7069 Toll Free 800 558 5592 E Mail Perlick Perlick com www Perlick com Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Wiring Diagram Concessionaire Dispensers 12 ...