background image

© 2008

8

24” C-Series Operation / Installation Manual

© 2009

8

24” ADA-Compliant Series Operation / Installation Manual

Figure 7. Glass Wood Overlay Door Panel

Summary of Contents for HA24BB1L

Page 1: ...llow instructions WARRANTY REGISTRATION To request information or service the model number and serial num ber must be provided This information is located on the inside ceiling of the unit and on the...

Page 2: ...an the condenser every three months can cause the unit to malfunction This could void the warranty Never install the unit behind closed doors Be sure front lou vered toe plate is free of obstruction O...

Page 3: ...3 prong receptacle in accordance with applicable electri cal codes DANGER Failure to comply with the above electrical guidelines may result in possible injury death fire or loss of property UNPACKING...

Page 4: ...unit into the opening 2 Check that the following are level and square front face and interior opening installation opening and floor surface countertop bottom front edge IMPORTANT The floor under the...

Page 5: ...ard to remove Figure 5 3 Place bracket at the desired position Push the rear hook into the rear key slot Set front of bracket on the wall hook 4 Repeat for other bracket s 5 Push extenders completely...

Page 6: ...ositions are correct unlock should be up lock should be horizon tal Adjust as necessary 5 Install overlay with lock assembly to the door 6 Install lock bracket to the unit See Figure 7A 8A and 9A for...

Page 7: ...HINGE KITS Part number 67439R to switch to Right Hinging Part number 67439L to switch to Left Hinging Step 1 Support door in the open position as shown Remove Hinge Pin Step 2 Pull door to the side t...

Page 8: ...2008 8 24 C Series Operation Installation Manual 2009 8 24 ADA Compliant Series Operation Installation Manual Figure 7 Glass Wood Overlay Door Panel...

Page 9: ...2008 9 24 ADA Compliant Series Operation Installation Manual Figure 7A Door Lock Placement Glass Wood Overlay Door Panel...

Page 10: ...2008 10 24 ADA Compliant Series Operation Installation Manual Figure 8 Solid Wood Overlay Door Panel...

Page 11: ...2008 11 24 ADA Compliant Series Operation Installation Manual Figure 8A Door Lock Placement Solid Wood Overlay Door Panel...

Page 12: ...2008 12 24 ADA Compliant Series Operation Installation Manual Figure 9 Solid Wood Overlay Drawers...

Page 13: ...2008 13 24 ADA Compliant Series Operation Installation Manual Figure 9A Door Lock Placement Solid Wood Overlay Drawers...

Page 14: ...temperature especially at the top and cause the refrigera tion system to run longer Loading Product IMPORTANT Before storing perishables allow unit to run for a mini mum of 24 hours to allow temperat...

Page 15: ...other routing maintenance Cleaning To clean stainless steel exterior or interior surfaces use a soft non abrasive stainless steel cleaner to wipe down the surfaces Glass doors can be cleaned using any...

Page 16: ...ilding circuit breaker or fuse on Is the control set properly Is the condenser area clean The refrigerated compartment is warmer than usual Is the control set properly Is the light staying on Is the c...

Page 17: ...Department 8300 W Good Hope Road Milwaukee WI 53223 E mail us at warrantyserv perlick com To obtain product service replacement parts or accessories Use only genuine Perlick replacement parts and acc...

Page 18: ...bused operating with low voltage wiring not conforming electrical codes improperly maintained or modified The original Bill of Sale delivery date or serial number cannot be verified Defective parts ar...

Page 19: ...2008 19 24 ADA Compliant Series Operation Installation Manual...

Page 20: ...3223 1 800 558 5592 Fax 414 353 7069 www perlick com Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without warning 2011 24 ADA Compliant Series...