48” TWO DOOR AND DUAL-ZONE REFRIGERATOR/WINE RESERVE 

Operation/Installation Manual

NOTE: The colder temperature setting must always be applied to 

the compartment on the left. A minimum temperature difference 

of 6° between the left and right compartments is required.
Example: 42°

 

Left compartment and 48° right compartment is 

achievable. 40° Left compartment and 44° right compartment 

is 

not

 achievable.

LED Functions

The following table describes LED functions

LED

Mode

Function

ON

Compressor is on

Flashing

Delay, protection or 

Blocked start-up

ON

Defrost is on

Flashing

Manual or D.I. activation

ON

Alarm is on

Flashing

Alarm acknowledged

ON

Evaporator is on

SELECTING APPLICATIONS

The procedure for loading one of the default applications 

is:

1.  At start-up of the device, keep the 

 key pressed: 

the label “AP1” will appear;

2.  Browse the various applications (AP1-AP2-AP3-AP4) 

using the 

 and 

 keys;

3.  Select the desired application using the 

 key 

(“AP3” in the example) or cancel the procedure 

by pressing the 

 key; alternatively wait for the 

timeout;

4.  If the operation is successful, the display will show “y”, 

if not it will show “n”;

5.  After a few seconds the instrument will return to the 

main display.

Power-on +

Selecting Applications

HC48 

48” Application Temperatures

Model

AP1

AP2

AP3

HC48RW 

HC48WW (Zone 1)

Refrigerator 

(36°F)

N/A

Wine Reserve 

(55°F)

HC48RW (Zone 2)

Red Wine 

(55°F)

White Wine 

(45°F)

N/A

HC48RS Models

Model

Temp Range

Factory Set Point

HC48RS4

34° F (1.1°)

42°F (5.6°)

HC48WS Models

Model

Temp Range

Factory Set Point

HC48WS4

34° F (1.1°)

68° F (20°)

HC48RW Models

Model

Temp Range

Factory Set Point

HC48RW4

Left 32° F (0°) 

Right 40° F (4.4°)

Left 42° F (5.6°) 

Right 68° F (20°)

HC48WW

Model

Temp Range

Factory Set Point

HC48WW4

43° F (6.1°)

54° F (12.2°)

NOTE: An audible alarm will sound on any alarm condition. 

To silence the active alarm press and release any key on the 

controller. See the troubleshooting section for description of 

alarm codes and resolutions. 

Summary of Contents for HC48RS4

Page 1: ...ler Name Address___________________________ ______________________________________________ ______________________________________________ ______________________________________________ Phone Number__________________________________ Introduction Congratulations on your purchase of a Perlick commercial underbarproduct Thismanualhasbeenpreparedtoassist you in the installation of your cabinet and to a...

Page 2: ...6 Preparing the Cabinet 8 Adjusting Full Extension Shelving 8 Operation 9 Checking Product Temperature 9 Digital Temperature Control 9 Programming Button Definitions 10 LED Functions 10 Maintenance 11 Troubleshooting 13 Wiring Diagrams 14 SAFETY PLEASE READ all instructions completely before attempt ing to install or operate the unit Take particular note of the DANGER WARNING and CAUTION informati...

Page 3: ...e tapping not available Wine tapping not available Wine tapping not available CABINET CONSTRUCTION INT Interior Stainless Steel CABINET CONSTRUCTION EXT Exterior Sides Exterior Top and Grill Stainless Steel Exterior Back and Exterior Bottom Stainless Steel Door Exterior Customer Choice see below under Customer Options CABINET INSULATION Polyurethane Ecomate Wall Thickness 2 Door Thickness 2 DOORS ...

Page 4: ... CORPORATION NOT TO BE COPIED OR USED DETRIMENTAL TO OUR INTERESTS DR DATE 1 28 2016 JMP SCALE 1 12 J Dwg 95000 95316 slddrw SHEET 2 OF 2 95316 REVISIONS JMP PROPERTY OF THE PERLICK CORP A 50 1270 Area in which electrical outlet must be located 12 1 4 311 24 15 16 634 Min clearance for door swing 22 559 44 1118 11 3 4 298 20 5 8 523 6 7 16 164 6 3 16 158 9 5 8 245 26 9 16 674 18 1 8 460 18 3 16 46...

Page 5: ...Remove all crating material before operating Carefully inspect cabinet for hidden damage If damage is discovered file your claim immediately with the transport company Perlick is not responsible for damage in transit DANGER Do not use or store flammable liquids ie gasoline or vapors near the appliance to avoid fire INSTALLATION NOTICE The unit must NOT be totally enclosed or damage may occur Air c...

Page 6: ...ce may result in fire INSTALLING CASTERS OR LEGS OPTIONAL Attach bracket assembly to the bottom of the cabinet base using the 20 Philips head machine screws provided Attach casters or legs to the mounting bracket with 20 Philips head screws provided NOTICE To comply with NSF requirements cabinet must be sealed to floor or on legs casters or rollers PLACING THE CABINET To assure maximum performance...

Page 7: ...e counter top directly above the unit For sanitation purposes it may be necessary to seal the base of the cabinet to the floor This can be accomplished by laying a bead of silicone sealant between the base of the cabinet and the floor as shown by the figure below When sealing the cabinet to the floor make sure that the louvered front grille plate can still be removed for condenser maintenance and ...

Page 8: ...nd six full extension black vinyl coated wine shelves The shelves are removable and adjustable to accommodate oversized magnum bottles ADJUSTING FULL EXTENSION SHELVING CAUTION Shelves should be emptied and free of any product prior to moving or adjusting Pull the shelf out to its furthest position Locate the tabs in the middle of both extenders see extender tabs below Press tabs and pull out Repo...

Page 9: ...ate for a minimum of 24 hours to allow temperatures to stabilize When loading items into the unit leave a minimum of 1 inch clearance in front of internal louvers and fan guard openings blocking airflow will result in decreased performance CHECKING PRODUCT TEMPERATURE 1 To accurately check the temperature of product stored in the refrigerated compartment insert an accurate thermometer into a plast...

Page 10: ... label AP1 will appear 2 Browse the various applications AP1 AP2 AP3 AP4 using the and keys 3 Select the desired application using the key AP3 in the example or cancel the procedure by pressing the key alternatively wait for the timeout 4 If the operation is successful the display will show y if not it will show n 5 After a few seconds the instrument will return to the main display Power on Select...

Page 11: ...ers are the worst offenders Preventing Stainless Steel Rust Use non abrasive tools to clean stainless steel products Soft cloths and plastic scouring pads will not harm the steel s passive layer Clean with polish lines Some stainless steels have visible polishing lines or grain When visible lines are present always scrub in a motion parallel to the lines When the grain cannot be seen polish in a c...

Page 12: ...y Cleaner Turco Scale 4368 or Permag 57 Swab and soak with a clean cloth Let stand for 15 minutes or more according to directions on package then rinse and wipe dry Rust dicoloration or corrosion caused by cleaning agents containing hydrochloric muriatic acid or chlorine bleach 3M Scotch Pad type A grade fine Clean off the surface soil using cleaning methods above Then rub discolored or corroded a...

Page 13: ...oor opening occurred Has warm product just been placed in the unit On hot days and in warm room temperatures the system will run longer Condensation forms inside the refrigerated compartments This is normal during high humidity and frequent door openings Are the doors closing and sealing properly Condensation forms on the outside of the unit During periods of high humidity some condensation might ...

Page 14: ...NET LIGHT MACHINE COMPARTMENT BLACK BLACK BLACK BLACK BLACK BLACK EVAPORATOR FAN CONDENSER FAN CONTROL MASTER POWER SWITCH DC DRIVER 2 DC DRIVER 1 1 1A I320 C 14 10 AMP 5 15P CORD END NOT USED CAP ENDS GROUNDED ABOVE CONDENSER FAN 1B 1 1A 1026854 WHITE BLACK RED WHITE RED BLUE NORMAL CLOSED NORMAL OPEN 1026973 1 WHITE BLACK LIGHT SWITCH EVAPORATOR SENSOR WHITE RED RED BLACK 68755 CABINET LIGHT 1B ...

Page 15: ...ROL DC DRIVER 2 DC DRIVER 1 I320 C 14 10 AMP 5 15P CORD END GROUNDED ABOVE CONDENSER FAN 1B 1 1A 1026854 WHITE BLACK RED WHITE RED BLUE 1026973 1 WHITE BLACK LIGHT SWITCH EVAPORATOR SENSOR WHITE RED RED BLACK 68755 CABINET LIGHT 1B 1 1A WHITE RED BLUE LIGHT SWITCH BLUE BROWN DC DRIVER 3 WHITE BLACK RED BLACK RED BLACK CENTER FAN WHITE BLACK BLUE BLUE WHITE BLACK BLACK BLACK WHITE BLUE BLACK WHITE ...

Page 16: ...PERLICK CORPORATION 8300 W Good Hope Road Milwaukee WI 53223 800 558 5592 perlick com Form No Z2426 Rev 03 04 2022 ...

Reviews: