11

Form No.Z2325

18” SHALLOW-DEPTH SERIES

Operation/Installation Manual

Checking Product Temperature

To accurately check the temperature of the product 

stored  in  a  refrigerated  compartment,  insert  an 

accurate thermometer into a sealable plastic (non-

breakable) bottle, partially filled with water. Tighten 

the cap securely.

Place the bottle into the desired area for 24 hours.

Refrain from opening the unit during testing period. 

After 24 hours, check the temperature of the water. 

Adjust the control settings if necessary and re-test.

The units are pre-set to achieve the recommended 

temperature  range  when  installed  in  a  70°F 

ambient  environment.  Factors  which  affect  the 

internal  temperatures  of  the  cabinet  include  the 

following:

 

Temperature setting 

 

Room temperature where installed 

 

Number of times the door is opened and 

closed 

 

Length of time door is left opened 

 

Adjacent compartment temperature 

 

Style of door installed 

 

Door gasket and sealing 

 

Amount of time internal light is illuminated 

 

Installation in direct sunlight or near a heat 

source.

MAINTENANCE

WARNING

Shut  off  the  electricity  to  the  unit  before 

cleaning  the  condenser  and  other  routine 

maintenance.

Cleaning

To clean stainless steel exterior or interior surfaces, 

use a soft, non-abrasive stainless steel cleaner to 

wipe down the surfaces.

Glass  doors  can  be  cleaned  using  any  standard 

glass cleaner available on the market.

To  clean  interior  non-metallic  surfaces  and 

removable  parts,  wash  with  a  mild  solution  of 

soap and lukewarm water with a little baking soda. 

Rinse and dry thoroughly. Avoid getting water on 

lights, control panel, and fan motor.

CAUTION

Do not use abrasive cleaners or cloths on any 

of the interior or exterior surfaces or removable 

parts.

Cleaning the Condenser

The  condenser  should  be  cleaned  every  three  

months. The condenser is located behind the toe 

plate. Remove the toe plate and use a soft bristle 

brush and vacuum to remove dust and lint. Avoid 

damaging or crushing the condenser fins or tubing. 

Upon completion, re-install the toe plate.

CAUTION

Failure to clean the condenser could result in 

temperature loss or mechanical failure. Clean 

this area every three months.

Summary of Contents for HD24 SERIES

Page 1: ... and assure you of our continuing interest in your satisfaction 8300 West Good Hope Road Milwaukee WI 53223 Phone 414 353 7060 Fax 414 353 7069 Toll Free 800 558 5592 E Mail perlick perlick com www perlick com C US Table of Contents Introduction 1 Preparing the cabinet for use General Precautions 2 Installation Notes 2 Dimensions Diagram 3 Preparing the Space 4 Preparing Electrical Connections 4 U...

Page 2: ...e to clean the condenser every three months can cause the unit to malfunction This could void the warranty 3 Never install the unit behind closed doors ie closets small pantries etc Be sure front louvered toe plate is free of obstruction Obstructing free air flow can cause unit to malfunction and may void the warranty 4 Use only Perlick replacement parts Use of non Perlick parts can damage the uni...

Page 3: ...k is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice 3 Form No Z2325 18 SHALLOW DEPTH SERIES Operation Installation Manual Figure 1 Dimensions ...

Page 4: ...floor PREPARING ELECTRICAL CONNECTIONS A 115 volt 60Hz 15 amp circuit breaker and electrical supply are required A separate circuit is recommended Follow the National Electrical Code along with local codes and ordinances when installing the receptacle All Perlick units come equipped with a NEMA 5 15P 90 plug with a 5 cord minimum extending beyond the rear of the unit The electrical outlet must be ...

Page 5: ... brackets Refer to Figure 3 for mounting bracket locations IMPORTANT If installing on a concrete floor concrete fastners are required and are not included in the Anti Tip Kit UNPACKING AND MOVING THE UNIT CAUTION Do not cut cardboard sleeve covering the unit Cutting may result in damage to the exterior of the unit 1 Uncrate the unit on a flat level surface Remove the cardboard sleeve by removing t...

Page 6: ...Figure 3 and perform the following A Measure from the floor to the bottom of the front edge of the countertop B Measure the rear of unit cabinet from floor to top of cabinet at back corners C Adjust rear legs so B measurement equals A measurement Using an adjustable wrench or pliers turn legs counterclockwise to raise the unit or clockwise to lower the unit IMPORTANT Leveling legs should not exten...

Page 7: ... is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice 7 Form No Z2325 18 SHALLOW DEPTH SERIES Operation Installation Manual Figure 4 Wall Bracket ...

Page 8: ...he bracket pull the front end up and out then forward to remove Figure 5 3 Place bracket at the desired position Push the rear hook into the rear key slot Set front of bracket on the wall hook 4 Repeat for other bracket s 5 Push extenders completely into the unit Align the shelf grooves with the extenders and slide completely into the unit DOOR PANEL OPTIONS Perlick units offer a variety of door p...

Page 9: ...Lock Washer Screw Lock Bracket 1 Attach bracket to wood overlay 2 Insert lock body 3 Add and tighten nut 4 Add lock strike 5 Add lock washer and screw 6 Use key to turn the lock and verify that the lock and unlock positions of the strike are correct unlock should be up lock should be horizontal 7 Adjust lock if necessary 8 Attached overlay with lock assembly to the door assembly 9 Attach lock brac...

Page 10: ...g a solid door If manual switch is left on for an extended period of time it may increase the cabinet temperature especially at the top and cause the refrigeration system to run longer Loading Product IMPORTANT When loading items into unit do not block interal louvers and fan guard openings or performance will be decreased Temperature Control The controller is located at the top rear panel of the ...

Page 11: ...alled Door gasket and sealing Amount of time internal light is illuminated Installation in direct sunlight or near a heat source MAINTENANCE WARNING Shut off the electricity to the unit before cleaning the condenser and other routine maintenance Cleaning To clean stainless steel exterior or interior surfaces use a soft non abrasive stainless steel cleaner to wipe down the surfaces Glass doors can ...

Page 12: ...t isn t running Is there electrical power to the unit Is the building circuit breaker fuse on Is the control set properly In the condenser area clean The refrigerated compartment is warmer than usual Is the control set properly Is the light staying on Is the condenser area clean and free of obstruction Has the door been open for a long time or more frequent door openings occurred Are the internal ...

Page 13: ... for planning installation or product information Write Perlick Corporation Customer Service Department 8300 W Good Hope Rd Milwaukee WI 53223 E mail us at warrantyserv perlick com To obtain product service replacement parts or accessories Use only genuine Perlick replace parts and accessories Genuine Perlick parts and accessories are designed to work correctly with Perlick products and offer supe...

Page 14: ...Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice 14 Form No Z2325 NOTES ...

Page 15: ...Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice 15 Form No Z2325 NOTES ...

Page 16: ...8300 West Good Hope Road Milwaukee WI 53223 Phone 414 353 7060 Fax 414 353 7069 Toll Free 800 558 5592 E Mail perlick perlick com www perlick com Form No Z2325 Perlick Generations of Excellence ...

Reviews: