Perlick is committed to continuous improvement. therefore, we reserve the right to change specifications without prior notice.

Preparing the Cabinet for Use – 

Pass-thru back bar Cabinets

Form no. Z2279

rev 08.01.07

Parts List

  ■ 

(2) Shelves plus (1) Floor rack-per door.

  ■ 

Shelf Clips.

Suggested Tools

  ■ 

 #2 Phillips Screwdriver.

  ■ 

10” Crescent Wrench.

  ■ 

9

/

16

” allen Wrench.

  ■ 

5

/

16

” and 

3

/

8

” hex Socket.

  ■ 

Power Drill or Driver. 

Plumbing

before operating the cabinet, the condensate drain 
tube (furnished) must be connected. One end is 
attached to the barbed elbow on the evaporator 
condensate pan. the other end is inserted through 
evaporator drain hole and exits the bottom of the 
cabinet. the drain hole is located in the cabinet floor 
pan, behind the vertical door mullion.
the drain tube must be placed over a floor drain or 
into a condensate management system such as a 
“COnDenSate eVaPaWaY” pan and heater.

Electrical

the cabinet must be connected to a separately 
fused power source (see electrical specification
plate) and grounded in accordance with national 
and Local electrical Codes. Caution: Do not
attempt to operate the equipment on any other 
power source than that listed on the electrical
Specification plate.

Uncrating and Inspection

remove all crating material before operating. 
Carefully inspect cabinet for hidden damage. if
damage is discovered, file your claim immediately 
with the transportation company. Perlick is
not responsible for damage in transit.

Installing Legs 

(Optional)

attach four legs to the cabinet bottom. Use the 
supplied 

1

/

4

”- 20 x 

3

/

4

” hex head self-tapping 

machine screws.

Placing the Cabinet

Position the cabinet into place using rollers when  
necessary. 

Important:

 Proper air flow around the 

condensing unit is necessary for efficient operation. 
never obstruct the air flow in and out of the  
condensing unit.

Leveling the Cabinet

When the cabinet is in place, check installation with 
carpenter’s level. When level front to back and left 
to right, accumulated water will drain out of cabinet 
evaporator drain.

Electric Condensate Evapaway kit 

(Optional)

a 115-volt electric condensate pan can be installed 
underneath the cabinet to collect and evaporate the 
condensate from the cabinet evaporator. a 6 foot - 3 
prong plug is included. a separate circuit should be 
provided for the heater. the kit can be used only on 
cabinets with 4” minimum legs. it can not be used 
with platform or baseplate kits..

Installing base Plate 

(Optional)

attach brackets to cabinet bottom in holes pro-
vided. attach base plate to brackets. (See separate 
instructions, provided with kit). When returning 
cabinet to upright position, be careful not to bend 
brackets.

WARNING! — Self Contained Units

To avoid compressor damage,after returning  

cabinet to an upright position, let unit stand for  

24 hours before plugging it in and running the unit.

Summary of Contents for PR48

Page 1: ...losed warranty card and mail to the Perlick Corporation to register the warranty If the card is not returned the warranty period will begin from the date the equipment is shipped from the factory This...

Page 2: ...and copper tube evaporator epoxy coated coil Adjustable temperature control Self defrosting Pull out condensing unit for service and cleaning Compressor left standard ELECTRICAL 115V 60Hz 1 phase AC F...

Page 3: ...nd Walls Stainless steel Includes pilasters 2 vinyl coated shelves and floor rack per door and interior lights Exterior Front back top and sides stainless steel Bottom galvanized steel Door Hinging St...

Page 4: ...mage If damage is discovered file your claim immediately with the transportation company Perlick is not responsible for damage in transit Installing Legs Optional Attach four legs to the cabinet botto...

Page 5: ...Turn the adjusting screw counterclockwise to the left Temperature Control OFF Turn the adjusting screw completely counter clockwise to the O position until a click is noted The condenser fan motor tur...

Page 6: ...jumper 65051A 65051A Light bulb C15046 C15046 Light bulb guard 65099 1 65099 1 Light socket 63484 63484 Light switch 63303 63303 Lock 63762 63762 Space lock 63761 1 63761 1 Lock rail 65432 24SS or 65...

Page 7: ...is assembled as the top left bracket Top right bracket is assembled as the bottom left bracket STEP 9 Re insert top hinge pin STEP 10 Re assemble lock rail from STEP 3 Operations to Perform on Door S...

Page 8: ...N BOX TO CONDENSING UNIT MUST COMPLY WITH ALL LOCAL AND NATIONAL ELECTRICAL CODES CABINET JUNCTION BOX CONDENSING UNIT EVAPORATOR HOUSING GROUND WIRE JUNCTION BOX PRESSURE SWITCH FIELD INSTALLED POWER...

Reviews: