Magnum C3C Spreader Sprayer
Operator Manual
Refer to the cover page for restrictions regarding
reproduction or disclosure of this material.
Page 51
September/08
TROUBLESHOOTING PROBLEMS (continued)
Failure Mode
Check
Corrective Action
Spreader Sprayer does not
start
Check Honda return spring
over long rod running to
governor arm.
Replace spring – If you
squeeze the throttle partly you
can start and run unit until
new spring is installed
Failure Mode
Check
Corrective Action
Spreader Sprayer starts but
dies once placed into gear
Safety module needs
replacing. Call 1-800-346-
2001 ask for tech.
Failure Mode
Check
Corrective Action
Spreader output provides an
uneven pattern.
Check for blockage of the
spreader holes.
Move the rate adjustment
lever to the highest setting,
and with the engine at 3450
rpm, momentarily open the
shutoff plate to discharge any
clumps of material that may
have blocked a discharge
hole. Return the rate lever to
the calibrated setting and
check the pattern. If the
pattern is still uneven, remove
the material from the hopper
and clean the holes.