Permobil C400 Corpus 3G Lowrider
Troubleshooting R-net
TROUBLESHOOTING R-NET
Troubleshooting guide
The following troubleshooting guide describes a number of faults and events which may occur when you use your
wheelchair, together with suggested remedies. Note that this guide cannot describe all the problems and events which
may occur and you should always contact your service contact or Permobil in case of doubt.
EVENT
POSSIBLE CAUSE
REMEDY
The wheelchair cannot be started.
Batteries discharged.
Charge the batteries.
The cable connection to the control panel has
come loose.
Insert the cable in the control panel.
Main fuse switched to OFF position after, for
example, battery replacement.
Reset the main fuse. See page 54
Main fuse triggered.
See page 54
The wheelchair cannot be driven.
Battery charger connected.
Stop charging and disconnect the charging
cable from the wheelchair’s charging socket.
Brake release activated.
Reset the brake release.
Wheelchair locked with the security key.
Unlock the wheelchair. See the Owner’s man-
ual for more information.
The wheelchair ”switches itself off” after a cer-
tain period of inactivity (20-30 min.).
The electronics’ energy saving mode has
been activated.
Switch the wheelchair on again using the start
key on the control panel.
The wheelchair stops while being driven.
The cable connection to the control panel has
come loose.
Insert the cable in the control panel.
Main fuse triggered.
See page 54
The wheelchair can only be driven at reduced
speed. (Applies with an electric seat lift and
seat angle.)
Seat lift or seat angle raised too high. See the
Owner´s manual for more information.
Lower the seat lift or seat angle.
The wheelchair cannot be charged.
Main fuse switched to OFF position after, for
example, battery replacement.
See page 54
The charging fuse is triggered
Wait for 5 minutes. The fuse will be automati-
cally reset.
111
Summary of Contents for C400
Page 1: ...Service manual C400 Corpus 3G Lowrider ...
Page 2: ......
Page 4: ...Text ...
Page 5: ......
Page 8: ......
Page 10: ...Permobil C400 Corpus 3G Lowrider Introduction 10 ...
Page 12: ...Permobil C400 Corpus 3G Lowrider Serial Number labels 12 ...
Page 94: ...Permobil C400 Corpus 3G Lowrider Repairs 94 ...
Page 110: ...Permobil C400 Corpus 3G Lowrider Control system 110 ...
Page 123: ...Permobil C400 Corpus 3G Lowrider Cabling Owerview CABLING OWERVIEW Chassis 124 Seat 126 123 ...
Page 124: ...Permobil C400 Corpus 3G Lowrider Cabling Owerview Chassis 124 ...
Page 125: ...Permobil C400 Corpus 3G Lowrider Cabling Owerview 125 ...
Page 126: ...Permobil C400 Corpus 3G Lowrider Cabling Owerview Seat 126 ...
Page 127: ...Permobil C400 Corpus 3G Lowrider Cabling Owerview 127 ...
Page 128: ...Permobil C400 Corpus 3G Lowrider Cabling Owerview 128 ...
Page 131: ......
Page 132: ...A 205334 UK 0 www permobil com ...