4.2.10 Standby Seating Mode: Default – Axes mode
Sets how the axes are controlled in the standby seating mode
Standard:
The seating mode of the R-net system is selected. It is
controlled by the joystick movements. This setting is
only advisable if the action can be followed on a device
equipped with a display like a JSM or an Omni.
Axes Mode:
The axes are controlled locally. It is controlled by the
joystick movements. The active axis is indicated by a
led. This mode should be set when there is no display
available for the user. The maximum accessible number
of axes is limited to 4.
4.2.11 Number of Axes only pre V2.00: Default – 4
Sets the number of axes that can be controlled in the axes mode
!!! This parameter is only valid when you have a software version lower then V2.00!!
1 … 4
Setting this parameter to 1 allows you to access 1 axis
(axis 1), setting this parameter to 2 allows you to access
2 axes (axis 1-2), … You will never be able to access
axis 5 even if it is the only axis available on the system.