background image

5

ROHO Hybrid Elite Cushion Operation Manual

Cushion Setup

Warnings:

 -

DO NOT use a product that is underinflated or overinflated, because 1) the product benefits will be reduced or eliminated, resulting in an 

increased risk to skin and other soft tissue, and 2) the individual may become unstable and vulnerable to falling. Carefully follow the instructions 

for inflation, placement and hand check. If the product does not appear to be holding air, or if you are not able to inflate or deflate the product, 

see “Troubleshooting”. Immediately contact the equipment provider, distributor, or Customer Support if the problem persists. 

 - When possible, use hook and loop fasteners to further secure the cushion to the seating surface. Hook fasteners are available upon request.
 -

After setting up the cushion the first time, perform a hand check frequently, at least once a day. When the cushion is used by a different individual 

or in a different wheelchair, repeat cushion setup. Follow the hand check instructions in this manual. 

IMPORTANT! 

For dual compartment cushions, repeat all steps for both valves.

Inflate, cover, and transfer. 

1

Inflate

: Open the cover flap. For the Heavy Duty Cover, open the zipper.

a. 

Slide the hand pump nozzle over the inflation valve. Open the inflation valve. Inflate the 

cushion until all of the air cells feel firm. 

b. 

Close the inflation valve until it comes to a stop. Remove the hand pump. Make sure the 

inflation valve is closed. 

Note: To open, turn the inflation valve at least one full rotation. The inflation valve will spin 

freely when open.  

Close

Open

2

Cover:

 Make sure the cover is correctly installed. Refer to the instructions provided with 

the cover and the "Cover Removal and Replacement" section in this manual. 

Fig. 1

Fig. 2

3

Transfer: 

a. Place the cushion on the wheelchair with the air cells facing up and the non-skid surface 

of the cover facing down. The symbol on the cover showing the seated figure may be 

used to help orient cushion. (Fig.1) 

b. The individual should transfer to the wheelchair and sit in their usual sitting position. 

Confirm that the boniest prominences are supported by the air cells. The inflation valve 

should be in the front, on the left side of the seated individual. (Fig. 2)

Perform a hand check.

4

To perform a hand check, use the width of your fingers to check the amount of air in the cushion. When the cushion 

has the correct amount of air*, the individual is both immersed in the cushion and supported by air:
a. Slide your hand between the air cells and the individual, and feel for the lowest bony prominences. 

Suggestion: To 

help locate the bony prominences while performing a hand check, lift and lower the leg. 

b. Refer to the Hand Check Guide below to adjust the cushion. 

* The recommended 

distance between 

the lowest bony 

prominence and the 

hard surface is

½ - 1 in. (1.5 - 2.5 cm).

HAND CHECK GUIDE

 

IMPORTANT! 

For dual compartment cushions, check both compartments.

UNDERINFLATED!
Not able to move fingers. 
Not enough air in the 

cushion. 

Risk: Not supported by air.

OVERINFLATED!
Can move fingers too freely. 
Too much air in the cushion. 

Risk: Not immersed in the 

cushion.

CORRECT AMOUNT OF 

AIR!

Able to slightly move fingers. 

Immersed in the cushion and 

supported by air.

If the cushion is UNDERINFLATED: 

Add some air. Close the inflation valve. 

Perform a hand check again. Repeat until the 

cushion has the correct amount of air. 

If the cushion is OVERINFLATED:

 

Remove some air. Close the inflation valve. 

Perform a hand check again. Repeat until the 

cushion has the correct amount of air. 

If the cushion has the CORRECT 

AMOUNT OF AIR, it is ready to use.

Warning: 

Make sure there is at least 

½ in. (1.5cm) of air supporting the 

individual's lowest bony prominences.

Summary of Contents for ROHO Hybrid Elite

Page 1: ...s h a p e f i t t i n g t e c h n o l o g y ROHO Hybrid Elite Cushion Operation Manual ...

Page 2: ......

Page 3: ...gn patents and trademarks including DRY FLOATATION Hybrid Elite Hybrid Elite SR ROHO Sensor Ready shape fitting technology Smart Check and Yellow Rope Zytel is a registered trademark of DuPont Product information is changed as needed current product information is available at permobil com Contact Customer Support for previous versions of product information ROHO Inc is part of Permobil 2009 2021 ...

Page 4: ...ct use Important Safety Information Warnings Skin soft tissue breakdown can occur due to a number of factors which vary by individual Check skin frequently at least once a day Redness bruising or darker areas when compared to normal skin may indicate superficial or deep tissue injury and should be addressed If there is any discoloration to skin soft tissue STOP USE immediately If the discoloration...

Page 5: ...stalled used and maintained according to the instructions and warnings provided by the cushion manufacturer When the wheelchair is used as the vehicle seat the cushion should only be used with wheelchair frames that are equipped with securement points specified in ANSI RESNA WC 4 2017 section 19 WC19 or ISO 7176 19 and that have been successfully crash tested on a wheelchair in the forward facing ...

Page 6: ...d Elite Dual Compartment Cushion B Quick Disconnect Hybrid Elite SR IF YOU OWN A SMART CHECK The Hybrid Elite SR is equipped with Sensor Ready Technology and can be used with a Smart Check which is a cushion feedback system Smart Check can be used to find the individual s inflation level and help check their cushion For more information contact Customer Support Note If you own a Smart Check STOP H...

Page 7: ...2 3 Transfer a Place the cushion on the wheelchair with the air cells facing up and the non skid surface of the cover facing down The symbol on the cover showing the seated figure may be used to help orient cushion Fig 1 b The individual should transfer to the wheelchair and sit in their usual sitting position Confirm that the boniest prominences are supported by the air cells The inflation valve ...

Page 8: ...ently pull through the hole in the foam base corner Repeat for other side 4 Remove the cushion insert from the contoured foam base Cushion Insert Replacement 1 Place the cushion insert on the foam base lining up the hook and loop fastener strips Make sure the cushion insert is centered Press down to securely attach the cushion insert to the foam base 2 Insert the tubing through the hole in the foa...

Page 9: ...Support The cushion is not holding air Inflate the cushion Inspect for damage to inflation valve s hose s and the quick disconnect Hybrid Elite SR Confirm that the inflation valve s are completely closed Look for holes in the cushion If very small holes or no holes are visible follow the instructions in the Repair Kit provided with the product For damage to the inflation valve s hose s or quick di...

Page 10: ...d adhesive remover oil based lotions lanolin ozone gas ultraviolet light cleaning methods DO NOT expose to direct sunlight Recommendation When washing by hand use room temperature water Note Deflated air cells may be easier to thoroughly clean To deflate the air cells with the inflation valve s open roll up and or compress the cushion and then completely close the inflation valve s Hand Wash and D...

Page 11: ...ent DO NOT expose cushions to temperatures above 70 C 158 F which may damage cushion components For machine washing or disinfecting make sure the washing machine capacity is sufficient A washing machine that isn t large enough may not remove all soil or contaminants from a cushion Using a damaged cushion will reduce or eliminate the benefits of the cushion and increase risk to skin and other soft ...

Page 12: ...nsor Ready shape fitting technology Smart Check och Yellow Rope Zytel är ett registrerat varumärke som tillhör DuPont Produktinformationen uppdateras efter behov aktuell produktinformation finns tillgänglig på permobil com Kontakta kundtjänst för tidigare versioner av produktinformationen ROHO Inc är ett företag inom Permobil 2009 2021 Permobil Rev 2021 04 20 Följande produkter beskrivs i denna an...

Page 13: ...stor stil för att säkerställa korrekt användning av produkten Viktig säkerhetsinformation Varningar Nedbrytning av hud mjukvävnader kan inträffa på grund av ett flertal faktorer som kan variera från individ till individ Kontrollera huden ofta minst en gång per dag Rodnad blåmärken eller mörkare områden jämfört med normal hud kan vara tecken på ytlig eller djup vävnadsskada och måste åtgärdas Vid m...

Page 14: ...bältessystem Dynan måste monteras användas och underhållas korrekt och säkert samt i enlighet med de instruktioner och varningar som tillhandahålls av dynans tillverkare Om rullstolen används som fordonssäte får dynan endast användas med rullstolsramar som är utrustade med fastspänningspunkter som specificeras i ANSI RESNA WC 4 2017 avsnitt 19 WC19 eller ISO 7176 19 och som har godkänts i krocktes...

Page 15: ...lite Dual Compartment dynan B Snabbkoppling Hybrid Elite SR OM DU HAR EN SMART CHECK Hybrid Elite SR är försedd med Sensor Ready teknologi och kan användas med Smart Check som är ett feedbacksystem för dynor Smart Check kan användas till att ställa in rätt uppblåsningsnivå för personen i fråga och till att kontrollera dynan Kontakta kundtjänsten för ytterligare information Obs Om du har en Smart C...

Page 16: ...med luftkuddarna vända uppåt och överdragets halkskyddssida vänd nedåt Symbolen med den sittande figuren på överdraget kan användas som hjälp till att vända dynan åt rätt håll Figur 1 b Användaren ska sätta sig i rullstolen och sitta i sin vanliga sittande position Bekräfta att de nedersta utskjutande beniga kroppsdelarna stöds av luftkuddarna Uppblåsningsventilen ska befinna sig på framsidan till...

Page 17: ...igt genom hålet i skumplastbasens hörn Upprepa förfarandet på den andra sidan 4 Ta ut dyninsatsen ur den konturerade skumplastbasen Sätta in dyninsatsen 1 Placera dyninsatsen på skumplastbasen så att kardborrebanden är inriktade mot varandra Säkerställ att dyninsatsen är centrerad Tryck nedåt för att sätta fast dyninsatsen ordentligt i skumplastbasen 2 För in slangen genom hålet i skumplastbasens ...

Page 18: ...ntör distributören eller kundtjänst Dynan tappar luft Blås upp dynan Inspektera uppblåsningsventilen erna slangen arna och snabbkopplingen Hybrid Elite SR med avseende på skador Kontrollera att uppblåsningsventilen erna är ordentligt stängd a Se efter om det finns hål i dynan Om mycket små hål upptäcks eller om inga hål syns följer du instruktionerna för reparationssatsen som medföljer produkten V...

Page 19: ...nolin ozon samt rengöringsmetoder som innefattar ultraviolett ljus FÅR INTE utsättas för direkt solljus Rekommendation Använd rumstempererat vatten vid handtvätt Obs Tömda luftkuddar kan underlätta en ordentlig rengöring För att tömma luftkuddarna Öppna uppblåsningsventilen erna och rulla ihop och eller tryck ihop dynan och stäng sedan uppblåsningsventilen erna helt Tvätta och desinficera dyninsat...

Page 20: ...ssnar Dynorna FÅR INTE utsättas för högre temperaturer än 70 C 158 F eftersom detta kan skada dynans delar Vid tvätt och desinfektion i maskin säkerställ att tvättmaskinen är stor nog En för liten tvättmaskin klarar inte säkert av att avlägsna all smuts och alla föroreningar från dynan Användning av en skadad dyna minskar eller eliminerar fördelarna med dynan och ökar risken för skador på huden oc...

Page 21: ......

Page 22: ......

Page 23: ...T20194 Rev 2021 04 20 Print Date Qty 1501 South 74th St Belleville IL 62223 USA permobil com EUROPE Permobil Box 120 861 23 Timrå Sweden 46 60 59 59 00 permobil com ...

Reviews: