e bunt.doc
Rev. 14.06.2010
Seite /
Page
28 / 40
Perrot REGNERBAU CALW GmbH
Industriestraße 19-27 / D-75382 Althengstett / Germany
Telefon : 0049-7051-162-0 / Fax : 0049-7051-162–133
E-mail : perrot@perrot.de
/ E-mail Konstruktion : technik@perrot.de
7
Replacing the nozzle
Ensure sprinkler is not under pressure.
Loosen all 3 of the cover’s securing screws and remove cover.
Using a screwdriver, remove white retaining ring.
Pull sprinkler insert out of the housing
Push down the flange and secure the head with the retainer
Take off sprinkler head cover by levering the cover up at the notch using a small
screwdriver.
Rotate nozzle to the left using pliers and then pull out.
Retaining ring