TDP062e.doc
Rev.
02.06.2014
Page
13
/
21
Perrot
REGNERBAU
CALW
GmbH
Industriestraße
19
‐
29
/
D
‐
75382
Althengstett
/
Germany
Phone:
0049
‐
7051
‐
162
‐
0
/
Fax:
0049
‐
7051
‐
162–133
E
‐
mail:
perrot@perrot.de
/
E
‐
Technical
Department:
technik@perrot.de
7.2
Fitting
the
sprinkler
insert
Fit
O
‐
ring
onto
flange
and
lightly
grease
for
easier
assembly.
Fit
sprinkler
module
inside
housing.
Ensure
correct
alignment.
Push
flange
down
as
far
as
it
will
go.
Fit
retaining
ring.
Retaining
ring
must
be
fully
inserted
into
the
slot.
Unclip
snap
‐
fit
lid
from
the
housing.
Check
sprinkler
is
working
properly
as
per
point’s
5b
‐
5f.
Guide
ribs
Guide
housing
Sprinkler