Features and programming 

To enter the programming mode, press the button on 
the  device  2  times.  First  push  activates  the  button, 
which is signaled by LED starting to glow green. Quick 
second  push  shortly  after  the  first  leads  to  the 
programming  mode.  Successful  entry  into  the 
programming  mode  will  be  confirmed  by  a  sound 
signal. 

Pressing  the  button  will  switch  the  modes,  while 
pulling  the  trigger  allows  to  enable,  disable,  or  set 
levels for the modes.

 

 

 

 

 

 

Full feature description 

Function and 

LED color

 

Description

 

Burst

 

 

Green

 

When this mode is enabled, a 2 to 5 round burst is available instead of fully automatic 
fire. 
 
No  sound  signal  while  LED  glows  green  means,  that  the  burst  is  off.  2  to  5  signals 
indicate 2 to 5 round bursts accordingly. 

 

Attention!

  This  burst  is  based  on  motor  current  measurements,  which  is  one  of  few 

methods  of  cycle  detection  in  non-drop-in  mosfets.  It  may  not  work  perfectly  in  all 
replicas, resulting in different number of shots fired in burst than programmed.

 

AB

 

 

Blue

 

Active brake (AB) stops the motor after the shot, preventing the spring from remaining 
in a compressed state and eliminates double shots on semi in replicas with high rate of 

fire (“overspin”). 5 levels of braking strength are available –

 from 1 (weakest braking) 

to 5 (the strongest). Braking can be also completely disabled. It is advised not to  use 
braking all the time, if not necessary, or to use it on the lowest possible level, because 
strong  braking  negatively  impacts  the  service  life  of  motor  brushes  and  causes 
increased heating. 

Tip: 

Set your replica to semi, press, and hold the button on the unit, then pull the trigger. 

This will cause a single shot with strongest AB setting to be fired, making sure the main 
spring remains uncompressed. It is advised to do that when you finish shooting for the 
day. 

 
No sound signal while LED glows blue means, that the active brake is disabled. 1 to 5 
signals indicate braking levels from 1 (the weakest) to 5 (the strongest). 

 

Attention!

  While  precocking  is  on,  the  AB  setting  becomes  irrelevant.  However,  any 

programmed AB setting will be stored in memory and will become effective as soon as 
precocking is disabled.

 

Summary of Contents for AB++

Page 1: ...ll help you fully exploit this unit s potential and in case of encountering any problems you can look for solutions to them here Manufacturer Perun Barwicka 8 St 60 192 Pozna Poland e mail info peruna...

Page 2: ...e Perun AB has an integrated electronic fuse which will automatically cut the power off in case of a short circuit or when a gearbox jam is detected The fuse does not wear out and does not need to be...

Page 3: ...urst than programmed AB Blue Active brake AB stops the motor after the shot preventing the spring from remaining in a compressed state and eliminates double shots on semi in replicas with high rate of...

Page 4: ...ay vary depending on replica configuration No sound signal while LED glows white means that the ROF reduction is disabled 1 to 5 signals indicate reduction levels from 1 the smallest to 5 the greatest...

Page 5: ...used for troubleshooting problems with the replica or the electronics Reconnecting the motor will restore normal functioning of the unit Motor check only takes place at start up A disconnection after...

Page 6: ...blem Cause Solution Replica fires a 2 round burst in semi auto mode Motor and battery are too strong for the main spring which causes overspin Enable AB or precocking Too high precocking level Set pre...

Page 7: ...nit will be pressed the unit will signal that by changing the LED color for a moment Attention To enter Contacts check mode the motor must be disconnected first only then connect the battery Attention...

Page 8: ...pe ni wykorzysta potencja produktu Zawiera ona schemat instalacji a tak e opis i rozwi zanie podstawowych problem w sygnalizowanych przez uk ad Producent Perun ul Barwicka 8 60 192 Pozna E mail info...

Page 9: ...ry automatycznie uruchomi si w razie wykrycia zwarcia lub zaci cia w gearboxie Bezpiecznik nie ulega zu yciu oraz nie wymaga wymiany Wtyczka do akumulatora Perun AB wyposa ony jest w fabrycznie zamont...

Page 10: ...mo e si r ni od ilo ci zaprogramowanej Niekt re serie mog te zawiera inn ilo strza w ni pozosta e AB Niebieski Aktywny hamulec AB ang active brake pozwala zatrzyma silnik po oddaniu strza u aby zapobi...

Page 11: ...wego oznacza wy czenie DMR Mode 1 5 sygna w oznacza od 1 poziomu najkr tsza przerwa do 5 najd u sza ROF reduction Bia y Funkcja ta pozwala ograniczy szybkostrzelno repliki w trybie ognia automatyczneg...

Page 12: ...normalne dzia anie Uwaga Pod czenie silnika sprawdzane jest tylko podczas uruchamiania uk adu Roz czenie silnika po uruchomieniu nie zostanie zasygnalizowane Uruchomienie bezpiecznika Czerwony sta y...

Page 13: ...ecockingu Obni y poziom precockingu Awaria mechanicznych styk w Sprawdzi stan przerywacza oraz kostki stykowej w razie potrzeby wymieni na nowe Uk ad nie strzela ani nie wydaje adnych d wi k w a dioda...

Page 14: ...ni ty w wczas dioda zmieni kolor Uwaga Aby wej w tryb kontroli styk w najpierw nale y roz czy silnik a dopiero potem pod czy bateri Uwaga Po uruchomieniu kontroli styk w tryb ten b dzie aktywny przez...

Reviews: