background image

 

4.

 

Factory settings 

 

New units and units where master reset was activated will have modes set in a following way: 

 

Burst 

 disabled 

 

AB 

 level 3 

 

Precocking 

 disabled 

 

DMR Mode 

 disabled 

 

ROF reduction 

 disabled 

 

Li-Po and Li-Ion alarm 

 enabled 

5.

 

Troubleshooting and diagnostic system 

Perun AB++ has a diagnostic system that will help you find the source, should you encounter a problem. 
After the battery is connected, the unit undergoes a start-up check, to make sure the replica is ready 
to work. Successful completion of this check is indicated by a short green blink of the LED. 

Diagnostic system can inform the user about following problems: 

Problem and LED color

 

Description 

Disconnected motor / Contacts 
check

 

 

Yellow, blinking 

This not only provides information about disconnection of the 
motor, but it is also a diagnostic mode for the trigger and the 
button  on  the  device.  With  disconnected  motor,  pulling  the 
trigger  or  the  pushing  the  button  will  cause  the  LED  to  glow 
purple  (trigger)  or  green  (button).  This  can  be  used  for 
troubleshooting problems with the replica or the electronics. 
 
Reconnecting the motor will restore normal functioning of the 
unit. 
 

Motor  check  only  takes  place  at  start-up.  A  disconnection 
after the start-up will not be signaled! 

Fuse activation

 

 

Red, continuous, or blinking 

Activation of the fuse with a distinction between a short circuit 
(continuous  red)  and  gearbox  jam  (blinking  red).  In  some 
situations,  this  distinction  may  not  be  correct,  for  instance  a 
gearbox jam may be incorrectly read as a short circuit and vice 
versa. 
 
Unit  will  start  functioning  normally  after  the  battery  is 
reconnected,  unless  there  still  is  a  short  circuit  that  will  be 
detected at next start-up. 

Trigger pull detected during  
start-up

 

 

Yellow and purple blinking 
alternately 

Unit detected that the trigger was being held during start-up. 
This  can  also  indicate  a  short  circuit  of  the  signal  wiring  or 
mechanical malfunction of the trigger mechanism. 
 
Unit will start functioning normally after the trigger is released. 

Button on the unit was pressed 
during start-up

 

 

Yellow and green blinking 
alternately 

Button on the unit was pressed during the start-up. 
 
Unit will start functioning normally after the button is released. 

Summary of Contents for AB++

Page 1: ...ll help you fully exploit this unit s potential and in case of encountering any problems you can look for solutions to them here Manufacturer Perun Barwicka 8 St 60 192 Pozna Poland e mail info peruna...

Page 2: ...e Perun AB has an integrated electronic fuse which will automatically cut the power off in case of a short circuit or when a gearbox jam is detected The fuse does not wear out and does not need to be...

Page 3: ...urst than programmed AB Blue Active brake AB stops the motor after the shot preventing the spring from remaining in a compressed state and eliminates double shots on semi in replicas with high rate of...

Page 4: ...ay vary depending on replica configuration No sound signal while LED glows white means that the ROF reduction is disabled 1 to 5 signals indicate reduction levels from 1 the smallest to 5 the greatest...

Page 5: ...used for troubleshooting problems with the replica or the electronics Reconnecting the motor will restore normal functioning of the unit Motor check only takes place at start up A disconnection after...

Page 6: ...blem Cause Solution Replica fires a 2 round burst in semi auto mode Motor and battery are too strong for the main spring which causes overspin Enable AB or precocking Too high precocking level Set pre...

Page 7: ...nit will be pressed the unit will signal that by changing the LED color for a moment Attention To enter Contacts check mode the motor must be disconnected first only then connect the battery Attention...

Page 8: ...pe ni wykorzysta potencja produktu Zawiera ona schemat instalacji a tak e opis i rozwi zanie podstawowych problem w sygnalizowanych przez uk ad Producent Perun ul Barwicka 8 60 192 Pozna E mail info...

Page 9: ...ry automatycznie uruchomi si w razie wykrycia zwarcia lub zaci cia w gearboxie Bezpiecznik nie ulega zu yciu oraz nie wymaga wymiany Wtyczka do akumulatora Perun AB wyposa ony jest w fabrycznie zamont...

Page 10: ...mo e si r ni od ilo ci zaprogramowanej Niekt re serie mog te zawiera inn ilo strza w ni pozosta e AB Niebieski Aktywny hamulec AB ang active brake pozwala zatrzyma silnik po oddaniu strza u aby zapobi...

Page 11: ...wego oznacza wy czenie DMR Mode 1 5 sygna w oznacza od 1 poziomu najkr tsza przerwa do 5 najd u sza ROF reduction Bia y Funkcja ta pozwala ograniczy szybkostrzelno repliki w trybie ognia automatyczneg...

Page 12: ...normalne dzia anie Uwaga Pod czenie silnika sprawdzane jest tylko podczas uruchamiania uk adu Roz czenie silnika po uruchomieniu nie zostanie zasygnalizowane Uruchomienie bezpiecznika Czerwony sta y...

Page 13: ...ecockingu Obni y poziom precockingu Awaria mechanicznych styk w Sprawdzi stan przerywacza oraz kostki stykowej w razie potrzeby wymieni na nowe Uk ad nie strzela ani nie wydaje adnych d wi k w a dioda...

Page 14: ...ni ty w wczas dioda zmieni kolor Uwaga Aby wej w tryb kontroli styk w najpierw nale y roz czy silnik a dopiero potem pod czy bateri Uwaga Po uruchomieniu kontroli styk w tryb ten b dzie aktywny przez...