IP Address – Enter the fixed IP address you wish to assign to the module
-
Subnet Mask – Enter the fixed subnet mask on which the RX module resides
-
Gateway – Enter the fixed gateway parameter you wish to assign to the module
Apply – Initiates the DHCP mode and IP address change
•
Factory Defaults
Clicking Factory Reset box restores factory default settings. You will be prompted to verify the
request before reset operation is performed.
4.7.5
C
USTOM
R
ESOLUTIONS
Vidblox receiver modules are pre-configured with data stream parameters for “standard” and many non-
standard video resolutions. It is possible that you may encounter a device attached to the RX module
video output signal that does not operate at any of the resolutions contained in the internal look-up-
table. To accommodate such occurrences, Vidblox allows you to configure up to three custom
parameter sets for specific video output signals that are configured and saved through the Custom
Resolutions function.
In order to set-up a custom resolution, you must know the resolution and timing parameters, such as
pixel count, clock rate and sync properties, for the device you are configuring. This information may be
contained in the user’s manual for the equipment or may be available on-line from the equipment
manufacturer. With some equipment you may have to search for sources of this information from video
support websites.