background image

2.

 

Never load and operate the scale above a creature. 

3.

 

Check if the right weighing unit is active (kg / lbs / N). 

4.

 

The owner and user of this scale are obliged to regularly check the snap-hook and the S-shaped hook, possible security clips, pins, screws, 
slings and cables in use and according to norms. If the before mentioned parts show any sign of looseness, defects or excessive wear 
immediately remove load from the scale and tighten, repair or replace the relevant parts. As product dealer we formally point out that we do 
not have the possibility nor the obligation to check the adherence to safety rules mentioned in this “safety guide” and in compliance to the 
norms and laws of the user country. 

5.

 

Longtime loading of the scale might lead to fatigue of the load cell. This might decrease the accuracy and shorten the lifespan of the scale. 

6.

 

Stop using the scale in case of extreme circumstances like flash, thunder and rain. 

7.

 

Do not operate the scale with low batteries [

]. 

8.

 

Do not attempt to repair the scale by yourself. Loss of warranty may occur. 

 

C  Application 

Versatile use for weighing in: Industry, construction, agriculture, service, research, environment, hunting, sports, fishery, household, hobby etc. 

D  Technical data 

 

 

Three Keypads 

 

on/off/tare

:  

- Press this key to switch on the unit when the scale is off. 
- Press this key to return to zero when the scale is on. This is also the tare function. 
- Press and hold this key for 

3 sec

 to turn off the scale when the scale is on. 

 

unit:

 Press this key to change the measuring unit between kg -> lbs -> N anytime during the weighing process. An indicating arrow on the right 

side of the display marks the active unit. 

 

hold

: Press this key to hold the weight reading for 10s. The display indicates the active function [H]. 

 

Battery Operation 

1.

 

When the display shows a battery sign” 

”, the batteries are low and need to be replaced. 

2.

 

Remove the battery compartment cover at the back of the scale. 

3.

 

Install 2 new AA 1.5V batteries observing their polarity. 

4.

 

Replace the compartment cover. 

5.

 

Remove the batteries if the scale is out of use for a longer period of time as leakage might damage the circuits. 
 

E    How to Operate the Scale 

 

For better reading remove the protecting foil from the display on first use of the scale. 

 

For best results, use the product in the specified optimum operating temperature. Acclimate the scale after radical temperature change, 
particularly before calibration. 

 

For best accuracy, use your scale vertically, in clean environment, free of electrostatic and magnetic fields, dust and dirt, moisture, vibration and 
air currents. 

 

Use your scale with care, gently loading items to be weighed. Avoid rough treatment in order to prolong the life of this precision instrument.

 

Switch on 

PHS100 

100kg · d = 100g / 220 lbs · d = 0.2 lb / 1000N · d = 1N 

Capacity · d = Graduation 

PHS200 

200kg · d = 200g / 440 lbs · d = 0.5 lb / 2000N · d = 2N 

Units 

kg / lbs / N 

Overload indication 

[O-Ld] 

Low voltage indication 

[

Optimum operating temperature 

0º - 40ºC / 32 – 104°F 

Power requirements 

2 batteries AA 1.5 V 

Net weight / gross weight 

600 g / 690 g 

Warranty of manufacturer 

2 years 

RoHS (Restriction of the use of certain Hazardous Substances)  conform 

Summary of Contents for PHS100

Page 1: ...elemente und Sicherungen sind gegebenenfalls festzuziehen zu sichern oder zu ersetzen Als H ndler streichen wir heraus dass wir weder die M glichkeit noch die Verpflichtung haben die Einhaltung der Si...

Page 2: ...eren andernfalls kann die Waage besch digt werden Funktion Hold Falls sich der zu wiegende Gegenstand bewegt z B Tier oder Gegenstand im Luftzug kann hold gedr ckt werden um den Anzeigewert f r 10 Sek...

Page 3: ...fekte und Montagefehler ein W hrend der Garantiezeit reparieren oder ersetzen wir gegebenenfalls defekte Teile zu unseren Kosten wobei das Produkt mit Frachtkosten vorausbezahlt zu uns gesandt werden...

Page 4: ...on unit Press this key to change the measuring unit between kg lbs N anytime during the weighing process An indicating arrow on the right side of the display marks the active unit hold Press this key...

Page 5: ...alibration weights available in the specialized trade or calibration by order to a calibration service 1 Before you switch the scale on hang it up vertically 2 Switch the scale on 3 Check if the selec...

Page 6: ...curit 1 Une surcharge de la balance n est pas admise La charge totale tare incluse ne doit pas d passer la charge maximale de la balance de plus de 50 affichage O_Ld 2 Ne chargez et n utilisez jamais...

Page 7: ...en marche Tenir ou suspendre la balance en position verticale Appuyer sur on off tare Tous les l ments LCD seront affich bri vement La balance ce se met z ro automatiquement signalis par un petit cerc...

Page 8: ...sur on off tare L cran affiche CAL suivi de PASS ce qui confirme un talonnage r ussit La balance passe au mode de pesage normale Si FAIL en place de PASS sera affich une faute d talonnage c est produ...

Reviews: