VB 230/400-25
11
11. Technical data
11.1 Ambient conditions
Note:
Please pay attention and consider for the operation of IE3 motors while
dimensioning of dc brakes the resulting higher starting currents.
For the use of IE3 motors we highly recommend to dimension and design
the needed braking devices one size higher.
Type designation VB ....
230-25
400-25
Mains voltage
according to DIN EN 50160 (IEC 38)
220/240V
±
10% 50/60Hz (standard)
380/415V
±
10% 50/60Hz (standard)
200 - 575V
±
10% 50/60Hz (wide-voltage range)
Power draw of the electronics
6 VA
Recommended for rated motor currents
up to
12,5A
Recommended for rated motor currents
on IE3 Motors up to
9A
Rated device current
25A
c.d.f. at max. braking current
8%
I²t - Value power semidonductor
1250 A²s
Braking voltage
0 ... 130VDC at 220/240V (standard)
0 ... 220VDC at 380/415V (standard)
0 ... 310VDC (wide-voltage range) (575V)
max. Braking time
15sec. (other times upon request)
Contact rating of the output relays
6A/250V AC
Delay time for reduction of residual e.m.f. self-optimizing
(100 ... 2500ms)
max. Cross-sectional area /
connecting cable
2 x 2,5mm² per terminal
Tigthening torque
max. 0.8Nm
Storage temperature
-25 ... 75°C
Operating temperature
0 ... 45°C
Degree of protection
IP 20
Environment
Overvoltage category III, pollution degree 2