MaINTENaNCE
102
Extendo and Traverse Operation and Maintenance Manual
800-GO-PETTIBONE
Thermostat Test
Place the thermostat in a pot of water and
1.
position a thermometer to indicate water
temperature. WaRNING! Burn Hazard. Wear
protective equipment.
Heat the water on a burner while observing the
2.
thermometer.
The thermostat should open when the
3.
thermometer indicates a water temperature of
180°f (82°C). If not, replace the thermostat.
Thermostat
1 –
Thermometer
2 –
Thermostat Test
figure 56.
Drive Belt Tension adjustment
The Cummins engine is equipped with a spring-
loaded tensioning device and requires no drive belt
adjustment.
Battery Replacement
Note: The Environmental Protection agency has
established guidelines for the disposal of
batteries. Make certain that EPa requirements
are met when disposing of batteries.
WaRNING! Chemical Burn Hazard. Wear eye
protection and rubber gloves.
Unfasten the hold down strap and remove the lid
1.
from battery box.
Remove the nut from each battery post.
2.
Remove the battery ground cable from the
3.
negative (-) battery post, then remove the
positive cable from the positive (+) battery post.
Loosen the two battery clamp nuts and lift the
4.
hold-down clamp from the battery.
Remove the battery box from the forklift.
5.
Position the new battery in the battery box.
6.
Replace the battery box in the machine.
7.
Place the battery hold-down clamp on the
8.
battery with the threaded rods of the clamp
hooked into the slots provided.
Tighten the hold-down clamp nuts.
9.
Position the battery cables on the posts in the
10.
following order: first the red cable to the positive
(+) post and then the black cable to the negative
(-) post.
Install a nut on each battery post.
11.
Replace the battery box lid and securely
12.
refasten hold-down strap.
Dispose of the old battery in a manner approved
13.
by the EPa.
Summary of Contents for Extendo 1032
Page 1: ...Operator s Manual PMOM 4021 736 744 936 944 1032 1144 1157 T944 T1157...
Page 2: ......
Page 8: ...vi Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE Contents...
Page 65: ...FORKLIFT OPERATION 57 Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE...
Page 67: ...FORKLIFT OPERATION 59 Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE...
Page 68: ...FORKLIFT OPERATION 60 Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE...
Page 70: ...FORKLIFT OPERATION 62 Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE...
Page 71: ...FORKLIFT OPERATION 63 Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE...
Page 73: ...FORKLIFT OPERATION 65 Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE...
Page 75: ...FORKLIFT OPERATION 67 Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE...
Page 77: ...FORKLIFT OPERATION 69 Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE...
Page 78: ...FORKLIFT OPERATION 70 Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE...
Page 80: ...FORKLIFT OPERATION 72 Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE...
Page 81: ...FORKLIFT OPERATION 73 Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE...
Page 83: ...FORKLIFT OPERATION 75 Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE...
Page 85: ...FORKLIFT OPERATION 77 Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE...
Page 87: ...FORKLIFT OPERATION 79 Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE...
Page 89: ...FORKLIFT OPERATION 81 Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE...
Page 91: ...FORKLIFT OPERATION 83 Extendo and Traverse Operation and Maintenance Manual 800 GO PETTIBONE...
Page 119: ......