After the wine cooler is plugged in, if temp is not set, the figure of temp will be marked 
automatically as 5

(40

) for upper chamber and 12

℃(

54

for lower chamber.   

The last setting temp will be memorized automatically by the system in the process of 
normal operation in the event of power supply cutting or stopping.   

 

     

SET(+/-)   

   

button for temp setting

 

When setting temp on upper chamber, if temp range is between 5-8

40-47

, the 

indicator below will be shown as orange, when the range between 9-12

48-54

the indicator below will be shown as white. 

When setting temp on lower chamber, if temp range is between 12-14

54-57

, the indicator below will 

be shown as white,    when the range between 15-22

48-72

, the indicator below will be shown as 

red. 

 

Temp setting for both upper and lower chamber is circulation type, setting can be stopped when 

temp  reaches  the  target,  the  control  system  will  have  a  judgement  for  3  seconds,  the 

corresponding digital tube will flash. If temp setting remains unchanged for 3 seconds, the control 

system will judge and confirmed the set temp, then returns to the indication of actual temp. 

 

POWER 

or OFF/ON This button controls starting and stopping of the software system. (the indicator for 

POWER on control panel 3 indicates system in power)   

 

℃/℉  

this button can switch Fahrenheit to Celsius or vice versa, their temp indication are corresponding. 

When switching, the corresponding indicator on the right corner of digital tube will start, and user can also 

choose the procedure of memorizing Fahrenheit when starting operation. 

 

 

Attention:   

According  to  different  habit  of  using  the  wine  cooler  among  different  countries  or  areas,  users 

can switch temp setting at will, only need to press the button “

/

”for 3 seconds     

 

LIGHT

 

LAMP

  This button can control starting and stopping of LED lighting.   

Summary of Contents for P120

Page 1: ...1 P80 P120 Manual USER MANUAL Model P80S P80D P120S P120D www pevino com ...

Page 2: ...the door all the way opened when pulling shelves out of the rail compartment The appliance must be positioned so that the plug is accessible Release the electric cord Move your cabinet to its final location Do not move your Cabinet while loaded with wine You might distort the body The wine cooler should be installed in a suitable place in order to avoid touching the compressor with the hand If the...

Page 3: ...n Clean the interior surface with lukewarm water using a soft cloth When replace the illuminating lamp please select the lamp which comply with the rated power input of lamp according to the rating label Shut off the power supply before replacing the lamp When disposing your appliance please choose an authorized disposal site Installation of Your Wine Cooler Place your Wine Cooler on a floor surfa...

Page 4: ... appliance has the capability of the door opening from either the left or right side The unit is delivered to you with the door opening from the left side Reversing door direction is shown as below diagram 1 Take off screws on hinge cover on top of the cabinet and then separate the door from the cabinet 2 Remove screws and hinge supporter beneath the cabinet then reverse the door at an angle of 18...

Page 5: ...tivated carbon filter 一 appearance 二 function This item is intended for sterilizating and getting rid of abnormal taste inside the cabinet 三 how to maintenance Take it out of the cabinet in every quarter and expose it to the sun for a few ...

Page 6: ...6 hours before putting it back It can be used repeatedly 四 how to place it It can be put on any position between two shelves ...

Page 7: ...7 STRUCTURE AND FUNCTIONS 1 door hinge 2 LCD control panel 3 Led lighting 4 shelf for wine storage 5 door frame 6 safety lock 7 supporting feet ...

Page 8: ...NG WINE 4 4 8 3 40 47 temp setting control panel for single temp setting l POWER l LAMP switch for Led lighting l SET TEMP l F Celsius Fahrenheit switch l OFF ON l Intensity LED lighting control press 2 seconds can turn off lighting press the button to restore l Color change color of LED lighting The left LCD chamber indicates the setting temp ranging from 5 22 40 72 when temperature is set betwee...

Page 9: ...ight corner of digital tube will start and user can also choose the procedure of memorizing Fahrenheit when starting operation Attention According to different habit of using the wine cooler among different countries or areas users can switch temp setting at will only need to press the button for 3 seconds This button controls progressive increase or decrease of the temperature when temp range is ...

Page 10: ...ressor Dual zone control panel l POWER l LAMP switch for Led lighting l UPPER CHAMBER set temp on upper zone l LOWER CHAMBER set temp on single zone l F Celsius Fahrenheit switch l OFF ON l Intensity LED lighting control press 2 seconds to turn off lighting press the button to restore l Color change color of LED lighting Dual zone temp control system is characterized by dividing the cabinet into d...

Page 11: ...ype setting can be stopped when temp reaches the target the control system will have a judgement for 3 seconds the corresponding digital tube will flash If temp setting remains unchanged for 3 seconds the control system will judge and confirmed the set temp then returns to the indication of actual temp POWER or OFF ON This button controls starting and stopping of the software system the indicator ...

Page 12: ...ystem of wine cooler but every starting and stopping the system won t start until 5 seconds after delay protection Self detection When power is on for the whole cabinet by touching button power mode of self detection will start In the process of detection the figure on digital tube will be circularly lighted up all the electrical ports will be put into power from which we can judge whether the who...

Page 13: ...13 2 For wine cooler with standard base ...

Page 14: ...n t place your cabinet close to such heat radiating appliances as furnace stove and radiator these items will increase power consumption of the cabinet To avoid putting the cabinet in damp environment For any query regarding power supply please consult with the authorized service center cleansing and maintenance EXTERIOR CLEANING Please cleanse the outer shell and door sealing of your cabinet with...

Page 15: ...t closing or fuse burnt out When temp inside the cabinet is not low enough check up the set temp frequently open the door door not closed tightly improper sealing abnormal voltage Lamp not illuminated Not turn on the lighting socket unconnected circuit closing or fuse burnt out Lamp break down vibrating to check up if the cabinet is laid flat ...

Page 16: ...16 door cannot be closed tightly unsteady placing door improper installation sealing break down wooden shelf get too close to the door odor inside the cabinet Remove the articles sending off odor 5 ...

Reviews: