Control requirement for cooling circulation system:
When cooling system inside the cabinet meet with requirement of temp setting, compressor will stop
working. When temperature inside the cabinet rises up to the level which requires compressor to start, it’ll
enter the process of re-starting, ≥ 5 minutes is required each time for stopping of the compressor. If
operating the button POWER to control cooling system of the whole cabinet, 5 minutes interval for delay
protection is required to re-start the compressor.
Dual-zone control panel
l
POWER:
l
LAMP: switch for Led lighting
l
UPPER CHAMBER: set temp on upper zone
l
LOWER CHAMBER: set temp on single zone
l
℃
/°F: Celsius/Fahrenheit switch
l
OFF/ON:
l
Intensity: LED lighting control, press 2 seconds to turn off lighting, press the button to restore
l
Color
:
change color of LED lighting
Dual-zone temp control system is characterized by dividing the cabinet into dual temp control
compartment(upper chamber and lower chamber) through combination of circuit control system, sheet
metal forming process and cooling system.
UPPER CHAMBER
:
5-12
℃
(40-54
℉
)
,
UPPER CHAMBER: temp control ranges from
5-12
℃
(40-54
℉
)
,
LOWER CHAMBER
:
12-22
℃
(54-72
℉
)
LOWER CHAMBER temp control ranges from
12-22
℃
(54-72
℉
)